4 Technical data

4.1 Combihammer
Note
For details of the rated voltage, current, frequency and input power, please refer to the power tool's
country-specific type identification plate.
If the tool is powered by a generator or transformer, the generator or transformer's power output must
be at least twice the rated input power shown on the rating plate of the tool. The operating voltage of
the transformer or generator must always be within +5% and -15% of the rated voltage of the tool.
Weight in accordance with
EPTA procedure 01
Single impact energy in accor-
dance with EPTA procedure
05/2009
Ø hammer-action drill bits (TE-
C)
Ø hammer-action drill bits (TE-
T)
Ø drill bits for wood
Ø drill bits for metal
4.2 Noise information and vibration values determined in accordance with EN 60745
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one electric tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the electric
tool. However, if the electric tool is used for different applications, with different accessory tools, or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This may significantly reduce exposure over the
total working period. Identify additional safety measures to protect the operator from the effects of noise
and/or vibration, for example: maintenance of the electric tool and the accessories, keeping the hands warm,
organization of work patterns.
Noise information
Sound (power) level (L
WA
Uncertainty for the sound
power level (K
)
WA
Emission sound pressure level
(L
)
pA
Uncertainty for the sound pres-
sure level (K
)
pA
Information about vibration
Drilling in metal (a
)
h,D
Hammer drilling in concrete
(a
)
h,D
14
English
Printed: 17.03.2017 | Doc-Nr: PUB / 5070952 / 000 / 02
TE 40
5.5 kg
4.9 J
5 mm ... 28 mm
6 mm ... 32 mm
6 mm ... 32 mm
6 mm ... 13 mm
TE 40
)
104 dB(A)
3 dB(A)
93 dB(A)
3 dB(A)
TE 40
≤ 2.5 m/s²
16.3 m/s²
TE 40­AVR
5.6 kg
4.9 J
5 mm ... 28 mm
6 mm ... 32 mm
6 mm ... 32 mm
6 mm ... 13 mm
TE 40­AVR
105 dB(A)
3 dB(A)
94 dB(A)
3 dB(A)
TE 40­AVR
≤ 2.5 m/s²
10.7 m/s²