Care and maintenance
Filter change
Before doing any work on
the machine, pull the plug
out of the socket.
Kasutada ainult WELLERi
originaalvaruosi.
Note
Different fluxes and flux
constituents and the amount
of and size of dust partic-
les in the extracted air will
signifi cantly effect the filters
working life.
Submicron particles in the
extracted air increase when
soldering or welding to var-
nish insulated wire.
Error messages and error clearance
Message/symptom
Extraction power missing
Loud extraction noises
Zero Smog is not running
Filter display is not working
Sub-micron paricle becoming
dirty to quickly
Unable to detect USB medium
Reset unit
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com
The degree of clogging of the filter is determined by differential
pressure measurement. The filter display indicates the current filter
status
Red = filter full
Yellow = filter status > 80%
Green = filter status < 80%.
When the filter is used up, an audible signal sounds
once an hour
every half hour after 36 hours
every 10 min after 54 hours
continuously after 72 hours.
The suspended matter filter and the broadband gas filter are comple-
mentary to one another and can be replaced together as a compact
filter. The fine dust filter (filter mat) is the preliminary stage of the
compact filter (17) and therefore must be replaced more frequently. It
is sufficient to replace the prefilter mat if the red LED does not come
on after restarting the unit.
Possible cause
Pipe system leaking
Filter is dirty
Turbine speed too low
Air speed through extraction-
arm is too high speed
Thermally switched off
Minimum pressure hose was
not replaced after the filter
change
Pre-filter has not been used
USB medium inserted too long
Wrong USB medium > 100
mA
Remedial measures
Reseal the pipe system
change the filter
Increase the speed setting
Reduce the air speed (reduce
air quanitity)
Leave the Zero Smog to cool
down Switch on again
afterapprox. 3 hours
Reconnect the hose to the
filter
Use a pre-filter Fit an F7 filter
Use a preliminary seperator if
the proportion of solid matter
is high.
Do not leave USB medium
inserted for longer than 2
minutes. Remove USB
medium and switch unit off
and on again
Remove USB medium!
17