052109 Rauchmelder BR 5232
Operating Instructions
Roof peak
20
30 cm from walls and corners.
These hinder smoke movement
and in the case of fire, the alarm
only sounds when the smoke
concentration is very high.
Mounting near ceiling lamps
(e.g. halogen systems, fluores-
cent lamps) especially those
with a dimmer function, is also
to be avoided.
In areas with sloping and
peaked roofs, the smoke alarm
must be mounted 90 cm from
the highest peak, since air does
not move in the slope/point.
This results in the smoke being
detected too late.
Smoke
NOTE:
Mounting on a roof beam is ideal.
02.06.2009
BR 5232
19:19 Uhr