1,2: Art-Net – 3,4: sACN:
• Art-Net RDM is enabled on all ports.
• All ports are configured as outputs.
• Ports 1 and 2 are configured to Art-Net.
• Ports 3 and 4 are configured to sACN.
• The ports are configured to consecutive universes (port addresses). The user is asked to choose a start universe.
• The user is prompted by a separate dialog to choose whether to adjust the network settings. If he chooses to do so, the IP address is
set to the primary Art-Net IP address and the netmask is set to 255.0.0.0.
Art-Net, Office Network:
• Same as Art-Net but network is configured via DHCP.
FIRMWARE VERSION 1.00 AND OLDER
The Factory Presets menu entry of the main menu allows you to load one of the following factory defined presets on devices with firmware
versions released prior to version 1.01 (version 1.00 or older):
Art-Net:
• Loads default network settings (IP address set to primary Art-Net IP address).
• Art-Net RDM is enabled on all ports.
o Ports 1 – 4 are configured to Art-Net universes 0 – 3 (Art-Net sub-net: 0, Art-Net net: 0).
Art-Net, no RDM:
• Same as Art-Net, RDM disabled on all ports.
sACN:
• Network is configured via DHCP.
• Art-Net RDM is enabled.
• Ports 1 – 4 are configured to sACN universes 1– 4
1,2: Art-Net – 3,4: sACN:
• Loads default network settings (IP address set to primary Art-Net IP address).
• Art-Net RDM is enabled on all ports. Note: affects port 1 and 2 only while port 3 and 4 are configured to output data from sACN.
• Ports 1 and 2 are configured to Art-Net universe 0 and 1 (Art-Net sub-net: 0, Art-Net net: 0).
• Ports 3 and 4 are configured to sACN universe 3 and 4.
Art-Net, Office Network:
• Same as Art-Net but network is configured via DHCP.
Loading any of the presets disables independent Art-Net universes (Independent Universes).
DEVICE SETTINGS AND INFORMATION
ADDRESS DISPLAY MODE
Under Address Display Mode, a selection list is presented to you with the following options:
Decimal: Art-Net net, Art-Net sub-net, Art-Net or sACN universe and Art-Net sub-uni are displayed as decimal numbers.
Hexadecimal: Art-Net net, Art-Net sub-net, Art-Net or sACN universe and Art-Net sub-uni are presented as hexadecimal numbers with a
trailing h (e.g. F3h).
A bullet point is shown next to the currently active setting. Use the encoder wheel to select the desired setting and push [OK], to apply the setting.
WEB INTERFACE
1
Under Web Interface, a selection list is presented to you with the following options:
Enable: The web interface is enabled.
Disable: The web interface is disabled.
A bullet point is shown next to the currently active setting. Use the encoder wheel to select the desired setting and push [OK] to apply the
setting. Changing this setting, requires a restart of the node. A popup will ask for confirmation. Press [OK] to restart now or [Cancel] to abort.
This option of the device settings is only available as of firmware version 1.03.
•
Web interface only available on devices produced after 2017 (hardware rev. 1.0-b)