Cameo XNODE 4 Manual De Usuario página 20

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
BOOT SOFTWARE
The full version number of the boot software.
FIRMWARE
The full version number of the firmware.
HARDWARE
The hardware revision.
MAC ADDRESS
The MAC address of the node's Ethernet interface.
UIDS
The RDM UIDs (unique identifiers) of the four output ports. These are numbers that unambiguously identify any RDM device. Since each
output port may act as an RDM controller, each output port has assigned its own RDM UID.
RESTORE DEFAULT SETTINGS
The default settings can be restored under Home > Menu > Restore Default Settings. In this menu, you will be asked whether you want to
continue restoring all settings. Push [OK] to confirm or [Cancel] to abort.
The default settings can also be restored from the Device Settings Page of the web interface.
This function will restore all settings to the defaults:
 Name: CAMEO XNODE 4
 Short name: XNODE 4
 Art-Net net: 0
 Art-Net sub-net: 0
 Art-Net RDM: Disabled on all output ports
1
 Independent universes: Disabled (available on firmware version 1.00 and older)
 Art-Net version: Art-Net 4 (available with firmware version 1.01 and newer only)
 All outputs enabled
 DMX output mode (all ports): Relaxed (firmware versions 0.99 and 1.00: Max. frame rate)
 Art-Net universe output 1-4: 0-3
 Failure behaviour (all outputs): Hold last look
 Merge mode (all outputs): HTP
 IP address: 2.X.Y.Z (primary Art-Net IP address)
 Netmask: 255.0.0.0
 Address display mode: Decimal
 LEDs: Unmuted
 Screen saver: Enabled
 User input locking: Disabled, password not set
 Web interface: Enabled (available with firmware version 1.03)
ETHERNET PORT STATUS INFORMATION
This screen is reached by pressing the Ethernet port button [E], which is located right next to the Ethernet port. See Device Overview for
more precise information about the location of this button.
This screen shows the following information about the status of the Ethernet port on four lines:
20
For firmware versions 0.99 and earlier, RDM enabled per default.
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Clxnode4

Tabla de contenido