Water
Filter
Data
System
Specification
and Performance
Data Sheet
®
Refrigerator
Water
Filter Cartridge
Model
9005
I Specifications
Service
Flow
Rate
(Maximum)
.............................................
075
GPM (2.83
L/min)
Rated
Service
Life
Model
9005
(Maximum)
.........................
500 gallons/
1892
liters
Maximum
Operating
Temperature
........................................
100 ° F/38 ° C
Minimum
Pressure
Requirement
..........................................
35 psi/ 138 kPa
Maximum
Operating
Pressure
..............................................
120 psi/827
kPa
General
Use
Conditions:
Read this Performance
Data Sheet
and compare
the capabilities
of this unit with your actual
water
treatment
needs.
The retractable
water
filtration
system
uses a 9005
replacement
cartridge
(see Sears
contact
information
at the front
of your
manual
to order).
Timely
replacement
of filter
cartridge
is essential
for performance
satisfaction
from this filtration
system.
Please
refer to the applicable
section
in this Use and Care Guide for general
operation,
maintenance
requirements
and
troubleshooting.
This system
has been tested
according
to ANSA1/NSF
42 and 53 for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less
than or equal
to the permissible
limit for water
leaving
the system,
as specified
in ANSI/NSF
42 and 53.
Performance
Data*
Influent
Challenge
Effluent
Average
%
Maximum
Min. Required
Inlet
Substance
Concentration
Average
Reduction
Effluent
Reduction
pH
Lead
0.15
mg/L +/- 10%
0.001
mg/L
99.33%
0.001
mg/L
0.010
mgiL
6.5
Lead
0.15
mg/L +/- 10%
0.002
mg/L
98.66%
0.003
mg/L
0.010
mglL
8.5
Cyst
Minimum
50,000/L
lcount/mL
99.99%
3 count/mL
>99.95%
NA
Turbidity
11+/-1 NTU
0.12 NTU
98.98%
0.18NTU
0.5 NTU
NA
Lindane
0.002
mg/L +/- 10%
0.00005
mg/L
92.06%
0.00005
mg/L
0.00002
mg/L
NA
Atrazine
0.009
mg/L +/- 10%
0.0002
mg/L
97.93%
0.0006
mg/L
0.003
mg/L
NA
Chlorine
2.0 mg/L +/- 10%
0.09 mg/L
95.26%
0.17 mg/L
_>75%
NA
Particulate**
at least 10,000
900 count/mL
99.68%
2400 count/mL
_>85%
NA
particles/mL
2,4-D
0.210
mg/L +/- 10%
45.45
ug/L
84.42%
100 ug/L
0.0017
mg/L
NA
Asbestos
107to l08 fibers/L;fibers greater 0.16
MFL/mL
99.96%
0.16
MFL/mL
99%
NA
than 10 micometersin length
Tested usin( a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa) under standard
laboratory conditions, however, actual performance
may vary. Health Claim Performance
tested and certified by NSF
international
** Particle size range classification
of test. Particles used were 0.5-1 microns.
Pentapure, Incorporated
1000 Apollo Road
Eagan, Minnesota
U.S.A.
EPA EST #35917-MN-1
Tested and Certified by NSF International against ANSI/ NSF Standards
42 & 53 in models WF50-KNI300
and WF50-KWI 500 for the reduction of.
Standard No. 42 Aesthetic Effects
Taste & Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particlate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead,A_azine,L#_dane & 2,4-DReductiorl
Mechanical Filtration Unit
Cyst, Turbidity,& Asbestos Reduction
]9
DO NOT use this product
where
water
is microbiologically
unsafe
or of unknown
quality
without
adequate
disinfection
before
or after the system.
System
certified
for cyst reduction
may
be used on disinfected
water
that may contain
filterable
cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE