Main Functions - Trevi ME 3105 Manual De Instrucciones Para El Uso Y La Conexion

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
English

1. Main functions

Displaying hour, minute, month, date, day of week, weather
forecast,temperature and humidity / 4 languages of week display:
English, German, French, Italian / RCC receive form: DCF / Day-
light Saving Time / 4 kinds of weather forecast: sunny, semi-sunny,
cloudy, rainy / 8 kinds of moon phase display / Single alarm
Blue LED backlight / Max/Min memory for indoor temperature and
humidity / Battery 2*AAA (not include)
2. FULL DISPLAY PHOTO
KEYS MODE SET UP DOWN C/F 12/24 MEM SNZ/LIGHT
NOTE MODE and SET are same function. UP and 12/24 are same
function. DOWN and C/F are same function.
3. Controlling instruction manual
1.1 Standard mode
Press MODE to check ALARM and TIME.
Press SET to set model.
Press MEM to check the MAX and MIN temperature and humidity.
Press MEM more than 2 seconds to clear all historical records of
temperature and humidity.
Press 12/24 to change 12H and 24H
Press C/F to change and Press DOWN more than 2 to exit RCC
receiving mode.
Press SNZ/LIGHT to light for 5 seconds
1.2 Time mode setting
Press MODE to set time. Setting order: Time→ Alarm→ Time In
time setting mode, hold SET into setting mode.
Setting item is twinkling at 1HZ frequency.
Setting order: zone→ hour→ minute→ year→ month →date
→Laguage →OFFSET
Press 'SET' to confirm setting.
Press 'UP' once and ahead; press for 2 seconds, go ahead at
speed 8 step/second.
Press 'DOWN' once and back; press for 2 seconds, go back at
speed 8 step/second.
Without any effect handling more than 30 seconds, it will exit setting
automatically and keep setting value.
Moon phase and week change with time setting.
1.3 Alarm setting
Press MODE change to alarm mode.
Hold SET to enter setting mode.
Setting item is twinkling at 1HZ frequency.
Setting order: hour → minute→ SNZ (You can setting snooze
time
between 1-20 minute the unit default in 5 minute →exit setting
Press SET to confirm setting.
Press UP once and ahead; press for 2 seconds, go ahead at an
8 step second speed.
Press DOWN once and back; press for 2 seconds, go back at an
8 step/second speed.
Without any effect handling more than 30 seconds, it will exit setting
automatically and keep setting value.
In alarm mode, press UP and DOWN to On/Off Alarm.
1.4 Alarm alert
BUZZER for 2minute
When alert, press SNZ/LIGHT into snooze function and press
other key to exit alert.
1.5 Temperature and humidity
Indoor temperature range 0 — +50
Indoor humidity range 20%-95%
1.6 Weather forecast
Weather forecast for next 24H.
Weather forecast: Sunny Semi-sunny Cloudy Rainy
Forecast can be more accurate under the natural ventilated
condition. Much error will be when indoor or in air-conditioned
environment.
1.7 Open or reset
The LCD display fully for 3 seconds when changing new battery
or resetting. Meanwhile backlight is on for 3 seconds, then with a
sound BI into the normal state, testing temperature and humidity,
last into RCC receiving.
Alarm defaults in 7:00. Temperature defaults in °C. Time defaults
as 24HR. Weather forecast defaults in semi-sunny. Perpetual
calendar default in 2009-1-1 0:00
1.8 RCC receiving
RCC receiving controlling:
1. When start or re-set, automatically receive RCC.
2.Press DOWN for 2 seconds to RCC receiving by force.
3. Automatically receive
Clock automatically receives RCC at 1:00 2:00 3:00 4:00 and 5:00
on each morning. It must receive at 1:00, 2:00 and 3:00. If fail
to receive at 3:00, it will continue to receive at 4:00 and 5:00. If
success at 4:00, it won't receive again intraday. Otherwise it will
continue to receive at 5:00, no matter clock success receiving or
not, after 5:00 am, it will be no longer receiving on that day. RCC
is received for 7 minutes at most.
RCC receiving picture
1. When entered RCC receiving, the RCC symbol will be blinking at
the frequency of 1HZ.
2. When received the signal, the RCC symbol will be static and the
arc figure will be blinking at the frequency of 1 HZ.
3. When the signal is weak and hard to find out the correct signal, the
symbol is blinking at the frequency of 1HZ. The arc figure will
disappear.
4. When succeed in receiving, the RCC receiving symbols will full
display
and exit receiving state.
When receiving, press DOWN for 2 seconds to exit RCC receiving;
press SNZ/LIGHT to light and other keys are no function.
If fail to receive intraday, the next receiving would be 1:00 am
at next day.
In the receiving RCC progress, meeting the alarm time, it will exit
RCC receiving and enter into alarm sound.
When received the DST (daylight saving time) signal, the DST
will display in the LCD.
When RCC symbol displays, if resetting the time, RCC symbol
will disappear.
1. Please re-power on when clock does not work or display unusual.
2. Battery should be replaced when display or sound is not clear.
3. Weather forecast is more accuracy in nature condition. It will be much
more differential when indoor, especial in air condition room. The function of
weather forecast is just for reference and not very accurate. When humidity
displays in ''--'', then the forecast shows nothing.
ME 3105
3

Publicidad

Tabla de contenido
loading

Tabla de contenido