Operator for roll-up doors
RULES TO AVOID ACCIDENTS DURING INSTALLATION
The connection of the motor to the power line should be performed only after completion of the installation
described below and only before the operation direction test and check of the limit. The operation direction test
and check of the limit switch should be carried out while maintaining at a safe distance from the crumple zone
of the door.
SPECIFICATIONS FOR INSTALLATION
The motor must be installed in a space provided with protection so that special tools only are needed for
assembly. This protection will prevent contact with the crumple zone of the door itself. The protection would
not be necessary if the installation is done at a height exceeding 2.7 meters. In case of Dead Man functioning,
the command position must be installed near the gate, in a position to allow the direct and complete
visualization of the same. In case of doors with empty elements, you must verify the absence of fixed structures
near the door, which can create zones of crushing. Photocells or sensors will be installed when required by
applicable laws. The use of photocells or sensors is required when you install more than one centralized
automated door or in case door is automated in an area that is not under direct control.
RULES TO AVOID ACCIDENTS DURING THE MAINTENANCE
Maintenance should be performed only after the motor has been prepared in safety mode. This is achieved by
activating the switch pole, making sure it does not turn off during the maintenance operation (lock, signalling,
etc.).
NOTE TO THE USER
DESCRIPTION OF THE PRODUCT
CONDITIONS OF USE
The EVO range 200/60 motors are intended for installation of doors winding systems by qualified personnel. The
EVO range 200/60 motors are designed and constructed for the installation of roller shutters provided with a
compensation system (by springs) according to the weight limits indicated in the table related to the technical
specifications. It is prohibited the use of the motor in applications other than those mentioned above.
TECHNICAL DATAS
Absorbed power
Lifting
Power supply
Current
Nominal torque
Pulley speed
Working temperature
Maximum door travel
Operation time
Weight of the motor
MOUNTING OPERATIONS
Drill in the shutter's central shaft (Fig. 4) one hole Ø 10 mm. in order the operator doesn't turn, and another Ø 12
mm. for the electric wire. If possible, place the operator in the centre of the shutter's shaft in an easy position for
opening the micro-switches lid to make the wire and the regulation of the limit switches. In case of electric brake,
make another drill of Ø 10 mm. for the cable of the manual release.
Open the pulley unscrewing the M8x25 screws remove the plastic roller band without folding it and keep it in a clean
place. Separate the gear-motor's body removing the 4 screws with the 6mm. (fig. 5A). hexagonal wrench.
Couple the two parts of the gear-motor around the door's shaft and joint them screwing the 4 screws on the gear-
motor's support (fig. 5B)
Tighten the M10x40 screw (Fig. 7 A) entering it into the Ø 10 mm. hole of the shutter's shaft.
Put again the plastic roller band in its place.
Apply again the pulley by coupling the two parts and tighten the screws.
Screw also the M10x40 (Fig. 7 B), bi-motor (fig. 9 B). Pressing on the shaft till the gear-motor is blocked and tighten
the nut.
The maintenance or testing of the gear is prohibited to unauthorized personnel.
Content (Fig. 1). Tools required (Fig. 2)
EVO 200/60 EVO 200/60E EVO 200/60 PLUS EVO 200/60 PLUS E EVO 200/60 BM EVO 200/60 BME
400 W
140 Kg.
130 Kg.
1.8 A.
135 Nm.
145 Nm.
5 '
6.67 Kg.
7.65 Kg.
600 W
170 Kg.
160 Kg.
II 230 V. 50/60 Hz +-7%
2.8 A.
175 Nm.
165 Nm.
10 r.p.m.
-20° C +50° C
6 m.
4.5 '
8.4 Kg.
7.42 Kg.
1200 W
305 Kg.
300 Kg.
5.6 A.
300 Nm.
295 Nm.
5 '
9.5 Kg.
10.5 Kg.
9