Dynapac SD1800C Instrucciones De Manejo Y Mantenimiento página 243

Tabla de contenido

Publicidad

KWP
SPN
FMI
1381
2
1180
0
1181
1
47
2
48
2
45
3
46
4
417
3
418
4
1182
0
1183
1
9
2
983
2
981
3
982
4
481
0
482
0
740
0
745
0
746
0
1448
0
1449
0
Code
Error Identification
8-3-9
Rail pressure safety function is not exe-
cuted correctly
3-1-8
Physikal range check high for battery
voltage
3-1-8
Physikal range check low for battery volt-
age
3-1-8
Battery voltage; system reaction initiated
3-1-8
Battery voltage; system reaction initiated
3-1-8
Sensor error battery voltage; signal
range check high
3-1-8
Sensor error battery voltage; signal
range check low
3-1-2
Sensor error environment temperature;
signal range check high
3-1-2
Sensor error environment temperature;
signal range check low
2-2-6
Physical range check high for intake air
temperature
2-2-6
Physical range check low for intake air
temperature
2-2-6
Sensor ambient air temperature; plausi-
bility error
2-2-6
Intake air sensor; plausibility error
2-2-6
Sensor error intake air; signal range
check high
2-2-6
Sensor error intake air sensor; signal
range check low
2-3-7
High low fuel temperature; system reac-
tion initiated
2-3-7
High Low fuel temperature; system reac-
tion initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
Short Text Detail
Rail pressure safety function is not executed
correctly
Physikal range check high for battery voltage
Physikal range check low for battery voltage
High battery voltage; warning threshold
exceeded
Low battery voltage; warning threshold
exceeded
Sensor error battery voltage; signal range
check high
Sensor error battery voltage; signal range
check low
Sensor error environment temperature; signal
range check high
Sensor error environment temperature; signal
range check low
Physical range check high for intake air tem-
perature
Physical range check low for intake air temper-
ature
Sensor ambient air temperature; plausibility
error
Intake air sensor; plausibility error
Sensor error intake air; signal range check high
Sensor error intake air sensor; signal range
check low
High low fuel temperature; warning threshold
exceeded
High Low fuel temperature; shut off threshold
exceeded
Physical range check high for oil temperature
High oil temperature; warning threshold
exceeded
High oil temperature; shut off threshold
exceeded
High customer oil temperature; warning thresh-
old exceeded
High customer oil temperature; shut off thresh-
old exceeded
D 23.18 81

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

911