KWP
SPN
FMI
1036
2
1044
3
1045
4
1026
2
1402
2
1403
2
1034
3
1035
4
34
3
35
4
648
1
649
2
825
9
833
10
171
9
198
9
179
9
919
14
565
4
566
4
567
12
840
2
838
3
D 23.18 92
Code
Error Identification
6-8-3
Sensor exhaust gas temperature
upstream (DOC); plausibility error
6-8-3
Sensor error exhaust gas temperature
upstream (DOC); signal range check
high
6-8-3
Sensor error exhaust gas temperature
upstream (DOC); signal range check low
6-8-4
Sensor exhaust gas temperature down-
stream (DOC); plausibility error
6-8-4
Sensor exhaust gas temperature (DOC)
downstream; plausibility error
6-8-4
Sensor exhaust gas temperature (DOC)
downstream; plausibility error
6-8-4
Sensor error exhaust gas temperature
downstream (DOC); signal range check
high
6-8-4
Sensor error exhaust gas temperature
downstream (DOC); signal range check
low
2-4-2
Controller mode switch; short circuit to
battery
2-4-2
Controller mode switch; short circuit to
ground
4-2-4
Manipulation control was triggered
4-2-4
Timeout error in Manipulation control
2-5-3
Pressure Relief Valve (PRV) reached
maximun allowed opening count
2-5-3
Pressure relief valve (PRV) reached
maximun allowed open time
3-3-3
Timeout Error of CAN-Receive-Frame
ComEngPrt; Engine Protection
3-3-7
Timeout Error of CAN-Receive-Frame
PrHtEnCmd; pre-heat command, engine
command
5-2-7
Timeout CAN-message FunModCtl;
Function Mode Control
1-3-1
Immobilizer status; fuel blocked
1-5-1
Injector cylinder-bank 1; short circuit
1-5-2
Injector cylinder-bank 2; short circuit
1-5-3
Injector powerstage output defect
1-4-3
Multiple Stage Switch constant speed;
plausibility error
1-4-3
Multiple Stage Switch constant speed;
short circuit to battery
Short Text Detail
Sensor exhaust gas temperature upstream
(DOC); plausibility error
Sensor error exhaust gas temperature
upstream (DOC); signal range check high
Sensor error exhaust gas temperature
upstream (DOC); signal range check low
Sensor exhaust gas temperature downstream
(DOC); plausibility error
Sensor exhaust gas temperature OxiCat down-
stream (normal operation); plausibility error
Sensor exhaust gas temperature OxiCat down-
stream (regeneration); plausibility error
Sensor error exhaust gas temperature down-
stream (DOC); signal range check high
Sensor error exhaust gas temperature down-
stream (DOC); signal range check low
Controller mode switch; short circuit to battery
Controller mode switch; short circuit to ground
Manipulation control was triggered
Timeout error in Manipulation control
Pressure Relief Valve (PRV) reached maximun
allowed opening count
Pressure relief valve (PRV) reached maximun
allowed open time
Timeout Error of CAN-Receive-Frame
ComEngPrt; Engine Protection
Timeout Error of CAN-Receive-Frame PrHt-
EnCmd; pre-heat command, engine command
Timeout CAN-message FunModCtl; Function
Mode Control
Immobilizer status; fuel blocked
Injector cylinder-bank 1; short circuit
Injector cylinder-bank 2; short circuit
Injector powerstage output defect
Multiple Stage Switch constant speed; plausi-
bility error
Multiple Stage Switch constant speed; short
circuit to battery