United Electric Controls 2SLP Instrucciones De Instalación Y Mantenimiento página 23

Tabla de contenido

Publicidad

POUR LES MODÈLES DE TEMPÉRATURE DISTANTS: ITINÉRAIRE DE FIL D'EXTENSION À ÉVITER TOUT CONTACT AVEC DES ÉLÉMENTS SOUS
TENSION OU À PROXIMITÉ DE SOURCES D' INTERFÉRENCES ÉLECTRIQUES. EVITER LES ÉTRANGLEMENTS OU FLEXIONS EXCESSIVES. SERREZ LE
RACCORD D'EMBOUT, LE CAS ÉCHÉANT.
POUR LA DÉTECTION DE TEMPÉRATURE D' UNE SURFACE, SÉCURISER LE CAPTURE SUR LA SURFACE EU UTILISANT DES MÉTHODES QUI SONT
APPROPRIÉ POUR L' APPLICATION ET QUI GARANTIE UN MAXIMUM DE TRANSFERT DE CHALEUR ENTRE LA SURFACE ET LE CAPTEUR.
REMARQUE: POUR TOUS LES MODÈLES DE TEMPÉRATURE QUI SONT LOCALEMENT INSTALLÉ (MODÈLES : C, H,R & L), L' UTILISATION L' UN PUITS
THERMIQUE ES FORTEMENT RECOMMANDÉ POUR AIDER À L'ENTRETIEN , LES ESSAIS ET LA PRÉSERVATION DE L'INTÉGRITÉ DU SYSTÈME . POUR
LES PUITS THERMIQUES EXISTANTS AVEC 0,375 "DE DIAMÈTRE, UN INSERT EST DISPONIBLE À COMMANDER EN UTILISANT LE CODE 62169-44.
L'ADAPTATEUR FOURNIT UN TRANSFERT DE CHALEUR PLUS RAPIDE EN ADAPTANT LE CAPTEUR DE TEMPÉRATURE DE DIAMÈTRE 0.250" À UN PLUS
GRAND PUITS THERMIQUE DE DIAMÈTRE 0.375". COMPOSÉ DE TRANSFERT DE CHALEUR EST RECOMMANDÉE DANS LE FOND DU PUITS THERMIQUE.
INSÉREZ LE CAPTEUR (0,250 " DE DIAMÈTRE) DANS LE PUITS, VEILLER À CE QUE LE FOND EST COMPLÈTEMENT IMMERGÉ DANS LE PROCÉDÉ
( 2,5 " MINIMUM ) AVEC LA POINTE DU PUITS THERMIQUE AU PLUS PRÈS DU CENTRE DU TUYAU QUE POSSIBLE. VISSER LE MAMELON DE LA
SONDE DANS LE PUITS THERMIQUE AVEC UN PRODUIT D'ÉTANCHÉITÉ , EN PLAÇANT UNE CLÉ SUR L'ÉCROU . AJUSTEZ LA POSITION DE L'ÉCRAN
DU TRANSMETTEUR ONE SERIES POUR UNE LECTURE FACILE. SERRER LE CONNECTEUR DE L'UNION POUR FIXER LE CAPTEUR DANS LE MUR.
POUR DE MEILLEURS RÉSULTATS, LE CAPTEUR DE TEMPÉRATURE DOIT ÊTRE EN CONTACT AVEC LA SURFACE OU LES MÉDIAS MESURÉS. UN
COMPOSÉ DE TRANSFERT DE CHALEUR PEUT ÊTRE UTILISÉE POUR AIDER À TRANSFÉRER COMPLÈTEMENT LA TEMPÉRATURE DU FLUIDE AU
CAPTEUR. LOCALISEZ LE CAPTEUR OÙ LA TEMPÉRATURE EST LA PLUS REPRÉSENTATIVE DE SYSTÈME. LA PROFONDEUR D'INSERTION MINIMUM
EST DE 2-1/2 ". DESSINS DES CAPTEURS SONT PRÉSENTÉS À LA PAGE 21 .
SE RÉFÉRER À LA PAGE 13 DU BULLETIN POUR SAVOIR LES DIFFÉRENTS TYPES DE RACCORDS ET ADAPTATEURS DISPONIBLES POUR FIXER LES
CAPTEURS DE TEMPÉRATURE.
AVERTISSEMENT: RISQUE D'EXPLOSION - POUR ÉVITER L'INFLAMMATION, COUPER L'ALIMENTATION AVANT DE RETIRER LE COUVERCLE DU BOÎ-
TIER. MAINTENIR LE COUVERCLE FERMÉ PENDANT LE FONCTIONNEMENT. NE PAS DÉCONNECTER L'ÉQUIPEMENT QUE LORSQUE L'ALIMENTATION
EST COUPÉE OU LORSQUE LA ZONE OÙ LE PRODUIT EST INSTALLÉ N'EST PAS UNE ZONE EXPLOSIVE.
AVERTISSEMENT: RISQUE D'EXPLOSION - NE PAS REMPLACEZ PAS L'INTERRUPTEUR DE SÉCURITÉ QUE LORSQUE L'ALIMENTATION EST COUPÉE
ET QUAND LA ZONE EST CONNUE POUR ÊTRE NON DANGEREUX.
DANS TOUS LES APPAREILS, LE FIL DE TERRE DOIT ÊTRE BRANCHÉ PROPREMENT.
CÂBLAGE SUR LE TERRAIN DOIT ÊTRE ÉVALUÉ 105 C MINIMUM . POUR UNE TEMPÉRATURE AMBIANTE INFÉRIEURE À -10°C, UTILISER LE CÂBLA-
GE APPROPRIÉ.
MODÈLES 2SLP EST ALIMENTÉ PAR LA BOUCLE ET DÉLIVRE UN SIGNAL 4 -20MA . L'ALIMENTATION FOURNISSANT DE L'ÉNERGIE À LA BOUCLE
DOIT ÊTRE DE CLASSE 2 OU À BASSE TENSION DE SÉCURITÉ «SELV» . LA CHARGE MAXIMALE POUR SORTIE DE RELAIS DE SÉCURITÉ ( SRO ) EST
INDIQUÉ DANS LE TABLEAU À LA PAGE 18 ET COMPREND TOUTES LES SPÉCIFICATIONS DE TEMPÉRATURE. SURCHARGE DE LA SORTIE DE RELAIS
DE SÉCURITÉ ( SRO ) PEUT PROVOQUER UNE PANNE . LE SRO NE DOIT PAS ÊTRE CONNECTÉ DIRECTEMENT À UNE SOURCE D'ALIMENTATION SANS
RÉSISTANCE EU SÉRIE APPROPRIÉE.
AVERTISSEMENT: DÉBRANCHER TOUS LES CIRCUITS D'ALIMENTATION AVANT DE BRANCHER L'APPAREIL. LE CÂBLAGE DOIT ÊTRE EFFECTUÉE
SELON LES CODES ÉLECTRIQUES NATIONAUX ET LOCAUX . TAILLES DE FILS RECOMMANDÉES ET COUPLES DE SERRAGE POUR LE CÂBLAGE SONT
PRÉSENTÉS À LA PAGE 4.
RETIRER LE COUVERCLE DU BOÎTIER DE RÉGLAGE 8 TOURS DANS LE SENS ANTIHORAIRE. RETIREZ DÉLICATEMENT LE MODULE D'AFFICHAGE PAR
LE BORD EXTÉRIEUR ET EN LE TIRANT TOUT EN FAISANT ATTENTION DE NE PAS FATIGUER LES FILS DE CONNEXION. LAISSER LE MODULE D'AFFI-
CHAGE ATTACHÉ POUR LE FIL DE MIS-À-TERRE POUR ACCÉDER À L'ENCEINTE DE BASE À TRAVERS L'OUVERTURE (S) DU CONDUIT DE L ENCEINTE
DE BASE. EFFECTUEZ LES CONNEXIONS COMME INDIQUÉ SUR LES SCHÉMAS DE CÂBLAGE, À LA PAGE 5 . DEUX MARQUES DE MIS-À-TERRE SONT
CLAIREMENT MARQUÉES SUR LE BOÎTIER DE BASE INTERNE ET ADJACENTE À TB3 EXTERNE ET JUSTE AU-DESSUS DE L'OUVERTURE DE CONDUIT SUR
LE CÔTÉ GAUCHE DE L'ENCEINTE.
POUR GARANTIR UNE BONNE FERMETURE DU COUVERCLE BOITIER , NE PAS ENLEVER LE LUBRIFIANT DE FIL. LES FILS DOIVENT ÊTRE VIDE DE
SALETÉ ET D'AUTRES CONTAMINANTS .
NETTOYAGE DE L'ÉCRAN ET LA SURFACE DU CLAVIER DOIT ÊTRE EFFECTUÉ AVEC UN CHIFFON HUMIDE . NE PAS ESSAYER DE LAVER LE PRODUIT
AVEC LE COUVERCLE RETIRÉ .
IM_ONE_Safety-03
www.ueonline.com
23

Publicidad

Tabla de contenido
loading

Tabla de contenido