the device in regular intervals.
Faults
Fault
No pressure builds up in
the device
pump.
The nozzle does not
sure is present.
there is no atomization.
not close.
Liquid emerges without
the lever being activated.
Pressure gage is not
pressure.
Cause
Cover is leaking.
The pump is not screwed on
O-ring [21] on the pump is
Diaphragm [22] is defective
fective.
Filter [46] and / or nozzle [23]
-
blocked.
Insert [24] is missing
O-rings [24] on the pressure
bolt not greased.
Defective pressure bolt [25]
or O-ring [24]
Pressure gage [15] defec-
tive.
Remedy
(Fig. 22h)
Replace the O-ring. (Fig. 20).
Replace the diaphragm.
(Fig. 21).
-
Clean or replace the valve disk.
(Fig. 20).
Position the insert in the nozzle.
(Fig. 18).
(Fig. 22a - 22h).
re bolt.
Replace the pressure bolt or
O-ring.
Unscrew pressure gage [15]
with wrench and replace.
(Fig. 24).
19
(Fig. 7b)
.
.
.
-