MOVEMENT
Before picking up or moving the machine you must check to in-
sure that the tank caps (G Fig. 3) are tightly shut. The generator
may be supplied with a rotating wheel. In this case, if the fl oor-
ing allows it you may push the generator like a cart. In the case
the machine does not have rotating wheels it is necessary to
unblock the hinge (P Fig. 4) located on one of the lateral struts of
the generator. Lower the handle from its "resting position" (Fig.
8) Turn the handle to the "Transportation Position" (Fig. 9). Lift
the generator and position it so that it is resting on the two an-
terior wheels.
Figur 8 - Position close handles
Figur 9 - Position open handles
WARNING: Before moving the machine you must: turn
the machine off by following the indications provided in
paragraph "TURNING OFF THE GENERATOR"; unplug
the electrical source by pulling the plug out of the wall
and waiting for the generator to cool down.
PREVENTATIVE MAINTENANCE
SCHEDULE
WARNING: Before beginning any maintenance operation
you must: turn off the machine following the instructions
in the "TURNING OFF THE GENERATOR" paragraph; un-
plug the electrical alimentation by unplugging the cord
from the wall plug and waiting for the generator to cool
down.
The instructions in this paragraph regarding the time between
service checks depend a lot on the cleanliness of the fuel and
the type of environment the generator is used in - the times giv-
en are for well-ventilated environments with little dust and con-
sidering the use of clean fuel.
Every 50 hours of operation you must:
• Dismantle the on-line cartridge (see "CLEANING THE FUEL
FILTER") extract and clean the cartridge.
Every 200 hours of operation you must:
• Dismantle the pump fi lter (see "CLEANING THE PUMP FIL-
TER) extract and clean it.
Every 300 hours of operation you must:
• Dismantle the burner and clean inside the burner's tube, the
fl ame disk and the electrodes regulating, if necessary the dis-
tance (see "CLEANING OF THE BURNER").
CLEANING THE FUEL FILTER
• Unscrew the plastic cup and extract the fi ltering element
(cartridge).
• Clean it well with kerosene.
• Insert the fi lter element back into its place and screw the cup
back into the main body of the combustion fi lter.
A.
Figur 10 - Filter
CLEANING THE PUMP FILTER
• Dismantle the burner coffer (F. Fig. 5), to identify the pump of
the burner (O Fig. 6).
• Unscrew the nut (A Fig. 11) that blocking the fi ltering element
to the pump.
• Extract the fi ltering element (C Fig. 11) outside its place.
• Clean it well with kerosene.
• Insert the fi ltering element back into its place and screw the
nut to the pump.
A.
A.
C.
B.
B.
D.
Figur 11 - Pomp of burner
5
GB
D.
A. O-rings,
B. Plastic cup,
C. Filtering
element,
D. Body of
C.
IN/OUT of the
fuel
B.
A. Nut for
C.
blocking the
pump fi lter,
B. Single elec-
D.
trovalve for
XL9 E doble
electrovalve
for XL9 S,
C. Filter,
D. Pump

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Xl9 s

Tabla de contenido