Electrical Requirements
Plug into a grounded 3- prong outlet.
Never remove the ground prong from the plug.
Never use an adapter.
Never use an extension cord.
Failure to follow these instructions can result in fire, electrical
shock or death.
Before you move your ice maker into its final location, be sure you have the proper electrical
connection:
A standard electrical supply (115V AC only, 60Hz, 15A), properly grounded in accordance with
the National Electrical Code and local codes and ordinances, is required. The ice maker should
always be plugged into its own individual electrical outlet.
It is recommended that a separate circuit, serving only your ice maker, be provided. Use
receptacles that cannot be turned off by a switch or pull chain.
The fuse (or circuit breaker) size should be 15 amperes.
Recommended grounding method
For your personal safety, this appliance must be grounded. It is equipped with a power supply
cord having a 3-prong grounding plug. To minimize a possible shock hazard, the cord must be
plugged into a mating 3-pronged and grounding-type wall receptacle, grounded in accordance
with the National Electrical Code and local codes and ordinances. If a mating wall receptacle is
not available, it is the personal responsibility of the customer to have a properly grounded,
3-prong wall receptacle installed by a qualified electrician.
Electrical Shock Hazard
10