C.
Cleaning Enclosure.
The circuit must be turned OFF and fixture globe MUST be allowed to cool to
ambient room temperature before cleaning.
The fixture should be cleaned periodically to maintain maximum light output.
Only mild, non-abrasive cleaning agents should be used. The dome should be regularly
inspected for scratches and chips, and if damaged, must be replaced.
D.
Service.
Federal Signal will service your equipment and provide technical assistance
with any problems that cannot be handled locally by Federal Signal's Distributor or
Manufacturer Representative.
Any unit returned to Federal Signal for service, inspection, or repair must be
accompanied by a Return Material Authorization number with a brief explanation of
the service being requested and/or the nature of the malfunction. This R.M.A. can be
obtained from the local Federal Signal Distributor or Manufacturer's Representative.
Address all communications and shipments to:
Federal Signal Corporation
Industrial Systems
Service Department
2645 Federal Signal Drive
University Park, IL 60466-3195
E.
Replacement Parts.
Description
Exterior Dome, Clear, 120VAC, 240VAC
12-24VDC, 225XST; 24VDC, 224XST;
24VDC, 225XST-I
Interior- Lens, Clear
Interior- Lens, Red
Interior- Lens, Blue
Interior- Lens, Amber
Interior- Lens, Green
Interior- Lens, Magenta
Flash Tube/Trigger Coil Assy.
Circuit Board Assy., 12-24 VDC & 24 VDC
Circuit Board Assy., 120 VAC
Circuit Board Assy., 230-240 VAC
In-Rush PCB Assy. (24VDC ONLY)
Gasket
NOTE
Part Number
K8444219-04
K8550C095A
K8550C095A-03
K8550C095A-01
K8550C095A-02
K8550C095A-04
K8550C095A-07
K8107177A
K2001202C-01
K2001905A
K2001905A-01
K2001918A
K8444286B