Installation Example - Truma MonoControl CS Instrucciones De Uso

Ocultar thumbs Ver también para MonoControl CS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43

Installation example

4
1 MonoControl CS gas tank
2 UV 10 changeover valve (part no. 25140-01)
3 30 mbar 10 mm, 50 mbar 8 mm gas pipes
4 DuoControl CS
Close extraction valve.
Screw the screw fitting (G.5) of the regulator inlet to the
extraction valve.
Do not twist pressure regulator after tightening the union
nuts. Twisting can result in leaking connections and move
the triggering element (A) into an angled position.
The triggering element (A) must always be in a vertical
position.
Connect the gas supply pipe to the regulator outlet
according to the respective installation instructions for olive
screw connections (e.g. EN ISO 8434-1). When tightening,
carefully use a second spanner on the provided spanner
surfaces to keep the entire assembly from turning.
For connecting to 30 mbar systems we recommend
the use of 10 mm gas pipes in order to ensure that the
required gas pressure is provided.
2
1
3
For 30 mbar systems with 8 mm gas pipes Truma can sup-
ply a straight reducer Z 10 / RVS 8 as an accessory.
Check inlet of gas pressure regulator for leaks (e.g. using a
leak finder spray in accordance with EN 14291).
When the installation operation has been completed, arrange
for the entire gas system to be leak-tested and checked by
a specialist technician to ensure correct installation. If a gas
testing certificate already exists it must be supplemented /
updated.
This test does not replace the regularly scheduled gas
check!
Then all functions must be tested in accordance with the oper-
ating instructions. The operating instructions must be handed
over to the vehicle operator.
13

Publicidad

Tabla de contenido
loading

Tabla de contenido