Specifi cations
Ranges:
Autoranging
AC Voltage:
600 Volts
AC Current:
600 Amps
Resistance (Ohms):
200 Ohms
Accuracy:
AC voltage +/- 1.5%
AC current +/- 2.0%
Resistance +/- 1.0%
Function/Range switch:
4 functions
4 positions
Sample Rate:
2 times / sec
Operation Temperature:
32oF - 104oF (0oC - 40oC)
Storage Temperature:
14oF - 140oF (-10oC - 60oC)
31/2 Digit LCD Display
Recessed Input Jacks:
Negative (-) input jack for black test lead, positive (+) input
jack for red test lead.
Batteries:
Two - „AAA"
Important:
Read this operators manual thoroughly before using this
meter. This manual is intended to provide basic information
regarding this meter and to describe common test procedures
which can be made with this unit. Many types of appliance,
machinery and other electrical circuit measurements are not
addressed in this manual and should be handled by experi-
enced service technicians.
Use extreme caution when using this meter. Improper use of
this meter can result in severe damage to property, severe per-
sonal injury or death. Follow all instructions and suggestions
in this operators manual as well as observing normal electrical
safety precautions. Do not use this meter if you are unfamiliar
with electrical circuits and proper test procedures.
9