Direct Electrical Connection To The Circuit Breaker, Fuse Box Or Junction Box - Sears Kenmore Elite 79046832101 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
2. Remove the 3 loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Connect the neutral white wire of the copper power
supply cord to the center silver-colored terminal of
the terminal block, and connect the other wires to
the outer terminals. Match wires and terminals by
color (red wires connected to the right terminal,
black wires connected to the left terminal).
4. Replace the 3 nuts on the terminal block. (See figure
3)
5. Lower the terminal cover and replace the 3 screws.
Figure 3
See below for 3 or 4 conductor wire connection.
Four Conductor Wire Connection to Range
(mobile homes)
1. Remove the 3 screws at the lower end of the rear
wire cover, then raise the lower end of the rear wire
cover (access cover) upward to expose range
terminal connection block (see figure 2).
2. Remove the 3 loose nuts (after you remove the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper
power supply cord to the frame of the appliance
with the ground screw, using the hole in the frame
(Models with an Electric Oven and a Gas Cooktop)
where the ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red
wires connected to the right terminal, black wires
connected to the left terminal).
6. Replace the 3 nuts on the terminal block (see figure
4).
7. Lower the terminal cover and replace the 3 screws.
Terminal Block
Black wire
1-1/8" Dia.
Direct
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
A
strainrelief
supplied by the
user
must be installed at
this location
NOTE: Be sure to remove the supplied
grounding strap
Direct Electrical Connection to the Circuit
Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L. listed strain-relief at each end of the
cable. At the appliance end, the cable goes through the
Direct Connection Hole (see Figure 4) on the Cord
Mounting Plate. Wire sizes (copper wire only) and
connections must conform to the rating of the appliance.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see Figure 5):(The 3-conductor cord or cable must be
replaced with a 4-conductor cord or cable where
grounding through the neutral conductor is prohibited in
new installations, mobile homes, recreational vehicles or
in other areas where local codes do not permit neutral
grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box
connect the appliance and residence cable wires as
shown in figure 5.
4
Silver Colored
Terminal
White Wire
(Neutral)
Ground
(Bare Copper
Wire)
To 240 V receptacle
Figure 4
Red
Wire

Publicidad

Tabla de contenido
loading