Maintenance; Safety Rules; Cleaning Of Machine; Safety Thermostat - Manual Resetting - MACCHIAVALLEY SELECTION Emotion Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SELECTION Emotion

6 - MAINTENANCE

To allow the proper machine's operation, fol-
low the maintenance instructions indicated
below.

6.1 Safety Rules

Do not subject the machine to a water jet.
Disconnect the machine from the power supply
by pressing the main switch and disconnecting
the mains plug.
In case of failure of the machine, avoid any
type of repair without assistance and immedi-
ately consult the technical assistance service.
In the event the feeder cord becomes dam-
aged, immediately switch off the machine, turn
off the water and contact the technical assis-
tance service. Avoid replacing it without assis-
tance.
Perform cleaning/maintenance operations when
the machine is cold, preferably wearing protec-
tive gloves for hands.

6.2 Cleaning of Machine

These notices are indicative, the maintenance
and cleaning schedules depend on the use of
the machine.
After each use
1) Clean the steam nozzle.
2) Clean the portafilter and the filters.
Daily
1) Clean the cup holding grid and the drain
basin.
2) Clean the machine body.
Weekly
1) Clean the group's gasket with the brush
supplied (Fig. 07).
2) Wash the brewing group as follows: Hook
the portafilter to the blind filter supplied
(Fig. 11) to the brewing group and initiate
output for a few times.
Monthly
1) Immerse the portafilter and the filters in hot
water for a few minutes to dissolve the cof-
fee oils, use a cloth or sponge to remove
it. To do this, loosen the coffee filter by twi-
sting it out of the portafilter.
For washing and cleaning opera-
tions, do not use solvents, deter-
gents or abrasive sponges. Wash
the body using a cloth soaked in wa-
ter and/or neutral detergents, and dry the sur-
faces well prior to connecting the machine to
the power line again. Use water to wash the
cup holding grid and the drain basin.
6.3 Safety Thermostat – Manual
Resetting
Warning! The operation described
below must always be performed
by a technician authorized by the
manufacturer.
When the machine is on, if the boiler's resis-
tor overheats, the safety thermostat is en-
abled, which interrupts the power supply,
thus preventing greater damage to the ma-
chine. To restore regular functioning, the fail-
ure that caused the safety thermostat to acti-
vate must be solved and the normal status
must be reset by pressing the red key (Fig. 08;
pos 1).

6.4 Proper Disposal of the Product

(electric and electronic waste)
(Applicable in the countries within the Euro-
pean Union and in those with separated waste
collection systems)
The label affixed on the product and
on the documents indicates that the
product must be disposed with other
domestic waste at the end of its life
cycle. To avoid potential harm to the environ-
ment or health caused by improper disposal of
waste, the user must separate this product
from other types of waste and recycle it res-
ponsibly to promote the sustainable reuse of
material resources.
Domestic users should contact the reseller
from whom they purchased the product or
25
EN

Publicidad

Tabla de contenido
loading

Productos relacionados para MACCHIAVALLEY SELECTION Emotion

Tabla de contenido