8.
Scope of Delivery
Item
Description
1
WC flusher with solenoid valve unit
2
Electronic module M2
3
Adapter cable
4
Cover plate
5
Frame
6
Fixing set
Installation and Operating Instruc-
tions
9.
Dimensions
10. Installation Example
11. Assembly Instructions
Warning!
• Operate the product only with safety extra low voltage (SELV). Do not earth the
components.
• The power supply (not included in the scope of delivery, see Accessories,
Chapter
18) must be set up outside of the wet area, in a separate room.
• Secure the electric connection with an earth leakage circuit breaker (RCD).
Failure to observe can mean risk of death or material damage, e. g. from electric
shock or fire.
☞
The system line (not included in scope of delivery) for connecting the power supply
to the fittings must be installed in a conduit (to be supplied by customer) and looped
through.
☞
Important!
Before installing, flush the pipes in compliance with DIN 1988.
11.1 Remove the shell protection.
11.2 Close the water volume regulators with a hollow hexagon wrench.
a: closed
b: open
- 6 -