Replacing The Plastic Hose; Fault Correction - Franke AQUA502 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19

16. Replacing the Plastic Hose

16.1 Remove the cover plate (see
16.2 Press the ring in the arrow direction.
16.3 Pull out the plastic hose.
16.4 Apply a slight pressure to push the plastic hose inwards to the stop.
16.5 Open the water volume regulator
16.6 Mount the cover plate.

17. Fault Correction

Fault
Water does not flow
Water flows conti-
nuously
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Chapter
15.).
(Work step
Cause
– Water supply interrupted
– Water flow regulator closed
– Solenoid valve faulty
– Opto-sensor faulty
– Electronic module defective
– Solenoid valve dirty
– Solenoid valve faulty
– Water volume regulator not fully
opened
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
- 9 -
11.2).
Remedy
➯ Restore it
➯ Open it
➯ Replace it
➯ Replace it
➯ Replace it
➯ Clean it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it

Publicidad

Tabla de contenido
loading

Tabla de contenido