DRAIN CONNECTION

• Connect the tube (6) supplied, at the connection (7) and
the other end to a drain, previously prepared.
IMPORTANT: The drain siphon must be
positioned below the support surface of the
machine by at least 20 cm.
LOAD CONNECTION
• Connect the hose (8), supplied, to the fitting (9) positioned
at the bottom rear of the machine.
• Connect the other end of the tube (8) to a softener.

IMPORTANTE:

the machine to a mains water supply with
drinking water suitably sweetened with a
maximum hardness of 3.5 / 5 ° French (60/85
ppm).
Check that the supply pressure does not exceed
4 bar (0.4 MPa). f the pressure is higher, install
a pressure reducer.
IMPORTANTE:
must be positioned a tap of capacity to separate
the network system plant from the plant of the
machine.
It is mandatory to connect
Upstream of the machine