Installation
!
WARNING!
 Do not tighten the threaded connections too firmly. Otherwise cracks
may form within hours or days.
 Before you start up the boat, check for any leaks. If you are unsure of
how to proceed, contact a qualified ship's mechanic. Otherwise there
is a danger of the boat sinking. This can result in death or injury to per-
sons.
8.9.2
Duct Kit Installation
I
NOTE
 Unit shown with blower rotated to vertical position.
 Dimensions and part numbers see "Scope of Delivery" on page 11.
Key to fig. 6, page 6
Item
1
2
3
4
5
6
7
8
9
10
11
12
13
26
Description
Ducting
Supply-air grille
Depth behind supply-air grille
Return-air grille
Control panel
Electrical harness
Condensate drain to sump
Hose barb assembly
Seawater outlet
Seawater inlet
Mounting bracket
Air conditioning unit
Electrical box
MCS6, MCS12, MSC16