6
PREPARING FOR INSTALLATION
DIMENSIONS AND CLEARANCES
Provide proper clearances between the range and adjacent
combustible surfaces. These dimensions must be met for
safe use of the range. The location of the electrical outlet
and pipe opening (see "GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS") may be adjusted to meet specific
requirements.
INSTALLATION CLEARANCES
Minimum to
cabinets on
either side
of the range
5"
18"
Minimum
clearance to
left wall
DIMENSIONS
30"
30"
Minimum
30"
Height
47
"
7 / 16
Depth with door open.
43
"
5 / 32
The range may be placed with 0" clearance (flush) at the
back wall.
5"
Minimum clearance
to right wall
36"
1/4"
Depth with door closed (includes door handle)
28
"
3 / 4
36" ±
Maximum
depth for
cabinets above
countertops
13"
Front edge of
the range side
panel forward
from cabinet
"
1/4
0"
To cabinets
below cooktop
and at the
range back