Message
1030 – Hood fault
Check hood, Then press
OK
1100 – Control panel
Control panel removed
during operation
1120 – Hood blocked
Check hood, Then press
OK
1125 – Remove obstacle
Check wire routing
1130 – Stuck
Free iMow, Then press
OK
1131 – Stuck
1135 – Outside
Place iMow in mowing
area
1140 – Too steep
Check wire routing
1160 – Handle actuated
Press OK to release
70
Possible Cause
No hood detected.
Control panel / manual controller has been
removed during. automatic operation
Permanent collision detected.
Perimeter wire routed inaccurately.
– Robotic mower has become stuck.
– Drive wheels are spinning.
See message 1130.
The robotic mower is located outside the
mowing area.
Tilt sensor has detected slope exceeding 22°.
The robotic mower has been lifted by the
carrying handle.
21 Troubleshooting Guide
Remedy
► Check hood (movement, firm seating) and
confirm the message with OK.
► Confirm the message by pressing the OK
button. Automatic operation resumes once
the control panel / manual controller has been
inserted.
► Free the robotic mower, remove the obstacle
or change the routing of the perimeter wire if
necessary.
► Confirm the message by pressing the OK
button.
► Check movement of the hood and confirm the
message by pressing the OK button.
► Check the routing of the perimeter wire and
check the clearances using the iMow Ruler.
► Free the robotic mower, level out the mowing
area or change routing of perimeter wire if
necessary.
► Clean the drive wheels, if necessary prevent
operation during rain.
► Confirm the message by pressing the OK
button.
► See message 1130.
► Return the robotic mower to the mowing area.
► Change routing of perimeter wire and block
off areas of the lawn with slopes exceeding
22°.
► Confirm message by pressing the OK button.