1. INTRODUCTION
This Meter is a handheld and battery
operated instrument that is designed and
tested according to IEC Publication 1010-
1 (EN 61010-1) (Overvoltage Category III),
the EMC Directive (EN 50081-1 and EN
50082-1) and other safety standards (see
"Specifications").
2. SAFETY CONSIDERATIONS
Before using this Meter, read the following
safety information carefully. In this manual,
the word "WARNING" is used for conditions
and actions that pose hazard(s) to the user,
the word "CAUTION" is used for conditions
and actions that may damage this Meter.
• Do not try to measure any voltage that
exceeds 1000V DC or 750V AC RMS.
• Voltages above 60V DC or 25V AC RMS
may create a serious shock hazard.
• Do not attempt to use this Meter if either
the Meter or the test leads have been
damaged.
• Turn off power the circuit under test
before cutting, desoldering, or breaking
the circuit. Small amounts of current can
be dangerous.
• Disconnect the live test lead before
disconnecting the common test lead.
• When using the test leads, keep your
fingers away from probe contacts. Always
grip behind the finger guards on the
probes.
• Use a current clap if measuring any
current above 10 Amps.
International Symbols:
WARNING Dangerous Voltage (Risk
of electric shock)
Alternating Current (AC)
Direct Current (DC)
Either DC or AC
Diode
Capacitor
Ground (Allowable applied voltage
range between the input terminal
and earth
CAUTION Refer to the user's manual
before using this Meter
Double Insulation (Protection
Class II)
Fuse
WARNING: OBSERVE ALL SAFETY
PRECAUTIONS WHEN MEASURING HIGHER
VOLTAGES (AND/OR CURRENTS). TURN OFF
POWER TO THE CIRCUIT UNDER TEST, SET
THIS METER TO THE DESIRED FUNCTION AND
RANGE, CONNECT THE TEST LEADS TO THIS
METER AND THEN TO THE CIRCUIT UNDER
TEST. REAPPLY POWER. IF AN ERRONEOUS
READINGIS
OBSERVED,
POWER IMMEDIATELY AND RECHECK ALL
SETTINGS AND CONNECTIONS.
Features.
• TDH @ 50/60Hz measurement.
• 3 3/4 digit, 4000 count with 41 segment
bar graph.
• Auto/manual ranging.
• Safety shutter to prevent incorrect
connections to current terminals.
• Fused 10 Amps range.
• Back-light.
• True RMS on AC Voltage and current
ranges.
• Standby mode indicator.
• DC Voltage basic accuracy within 0.3%.
• Fix hold™ (Automatic reading hold).
E N G L I S H
DISCONNECT
29