Elettro CF PRO MIG 466 PULSED Manual De Instrucciones página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
Key U1 Test gas - When this key is pressed, the gas
lows out for 30 seconds. If pressed again the low stops.
3.2.2.2. SETTINGS PANEL (Pict. 3, area Y).
Allows a quick access to the welding machine menu and to the
additional functions that are displayed and immediately
available. It consists of a matrix display V1 that shows all
information required to program the surfing keys (T5, T6, T7 and
T8) used to surf inside the menu. It also consists of function
keys (U5, U6, U7, U8 and U9) that allow access to the different
menus that make up the firmware and a series of leds that signal
the type of process in operation (U4, U3 and U2) and a few
additional functions (V4, V3 and V2).
Immediately after it shows the values preset by the welding
machine manufacturer
- Gas Ar/18% CO2.
- 2 stages Start-up mode 2T.
The lower portion of the display shows (MEM, PAR, 2T/4T and
JOB) that can be selected by means of the function keys U8,
U7, U6, U5 (see par. 3.7).
3.2.2.3. ALARM DISPLAY
When the machine detects a temporary alarm, displays V5 and
T4 show a lashing wording related to the alarm cause. FOR
example: if the wire feeder door is opened, the wording "OPn"
3.2.2.4. ERROR DISPLAY
When the machine detects a serious alarm, displays V5 and T4
show a wording "Err" followed by the relevant error code.
In this case, switch off the machine and contact technical service
(see par. 5).
3.3. MACHINE PROGRAMMING "Main Menu"
Programming is made in the "Main Menu". To access, press key
U9 and then key U8 (MENU) or through the quick access menu
described under paragraph 3.7.
In the "Main Menu ", via keys T5 and T7, it is possible to select
one of the list items highlighted by the yellow band. With key T6
enter the submenu, while with key T8 return to the previous
menu and save, at the same time, the selection made. A
When
the
welding
machine
starts, the display V1 shows for
about 5 sec., a few information
about machine status (see par.
3.6 Information menu) including
the firmware version.
-Date (day/month/year) and time
(hour and minutes).
-Synergic MIG Process. (Led U4
on).
-Welding wire type SG2 ø
1.0 mm.
downward arrow indicates that there are additional items not
shown on the screen.
This surfing mode applies to all machine menus.
The available items in the "main menu" are:
-
"Process Parameters" (See par. 3.3.1)
-
"Jobs" (See par. 3.4)
-
"Settings" - (See par. 3.5)
-
"Information" (See par. 3.6)
3.3.1.
"PROCESS PARAMETERS" MENU.
Submenu "Process Parameters" is accessed through the" Main
Menu" or directly by means of key U7 (PAR). Here are listed all
the parameters that the operator may modify according to the
selected welding process (LEDs U4, U3, U2).
In the "Process Parameters", you may save directly by pressing
key U8 (MEM) (see par. 3.4.1).
3.3.1.1. "Process".
that can be selected are:
MIG
Pulse synergic MIG/MAG welding.
MIG
Synergic MIG/MAG welding.
MIG HD
High deposit synergic MIG/MAG welding.
MIG Root Synergic MIG/MAG welding for drooping vertical
welding.
MIG Man Traditional MIG/MAG welding.
TIG
Welding process with non-meltable electrode suited
for all types of metals; aluminium, magnesium and
brass excluded. The arc strikes by contact without
high frequency.
MMA
Welding process with coated, meltable electrode.
3.3.1.2. "Material" (only in synergic MIG/MAG processes).
With this item you select the type of welding wire material.
3.3.1.3. "Diameter" (only in synergic MIG/MAG processes).
The welding wire diameters are related to the selected material.
3.3.1.4. "Gas" (in MIG/MAG processes).
Gas types that can be used are related to the selected material.
3.3.1.5. "Arc Length Corr" -Arc length correction.
(Available in synergic MIG/MAG, MIG Root).
Arc length corr.
WARNING:
the adjusting page, which is similar for all parameters with an
adjusting range, shows:
-
The parameter name being corrected.
-
The value and the unit.
-
The adjusting range.
-
The abbreviations:
MIN = minimum adjustment.
MAX = maximum adjustment.
DEF = preset value.
16
The first parameter is the welding
process. By pressing key T6 you
enter the Process Selection page.
By means of keys T5 and T7, you
select the item highlighted by the
yellow band but you also scroll all
available processes. The welding
It allows to correct the Volt Arc
length by means of keys T5 and
T7 or knob T3.
MIN
MAX
DEF.
-9.9V
9.9V
0.0V
Key U8
Key U6
Key U7.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pro mig 566 pulsed

Tabla de contenido