Indication channels
4.1.1
Indication of collector temperatures
COL, COL1, COL2:
Collector temperature
display range:
-40 ... +250 °C
4.1.2
Indication of store temperatures
TST, TSTL, TSTU,
TST1, TST2:
Store temperatures
Display range:
-40 ... +250 °C
4.1.3
Indication of sensor 3 and sensor 4
S3, S4:
Sensor temperatures
Display range:
-40 ... +250 °C
4.1.4
Indication of other temperatures
TFSB, TRET, TFL, TRF:
Other mea suring
tempe ratures
Display range:
-40 ... +250 °C
4.1.5
Indication of current pump speed
n %, n1 %, n2 %:
Current pump speed
Display range:
30 ... 100 %
4.1.6 POOL
POOL:
Swimming pool charging
Setting range: ON
Factory setting:
OFF ... ON
Shows the current collector temperature.
• COL
: collector temperature
(1-collector-system)
• COL1
: collector temperature 1
• COL2
: collector temperature 2
Shows the current store temperature.
• TST
: store temperature
(1-store-system)
• TSTL
: store temperature lower
• TSTU
: store temperature above
• TST1
: temperature store 1
• TST2
: temperature store 2
Shows the current temperature of the correspon-
ding additional sensor (without control function).
• S3
: temperature sensor 3
• S4
: temperature sensor 4
Please note:
S3 and S4 are only indicated if the temperature
sensors are connected.
Shows the current temperature of the correspon-
ding sensor.
• TFSB
: temperature solid fuel boiler
• TRET
: temperature heating reverse raising
• TFL
: temperature forward fl ow
• TRF
: temperature return fl ow
Please note:
TFL/TRF is only available in case of an activated
option heat quantity measurement (OHQM).
Shows the current pump speed of the correspon-
ding pump.
• n %
: current pump speed
(1-pump-system)
• n1 % : current pump speed pump 1
• n2 % : current pump speed pump 2
Enables the activation or deactivation of the
POOL function
17