How to Stop
Set the Off/Auto switch to "OFF".
Before First Start-up
Do not operate this unit until you read this instruction manual
for safety, operation and maintenance instructions.
Before Each Start-Up
1.
Place Off/Auto switch to "OFF" and close air regulator.
2.
Plug the power cord into the correct branch circuit receptacle. (Refer to
Voltage and Circuit Protection paragraph in the Installation section of this
manual.)
3.
Turn the regulator knob counterclockwise until it stops.
4.
Attach hose and accessories.
Risk of unsafe operation. Do not use damaged or worn
accessories.
Risk of Bursting. Too much air pressure causes a hazardous
risk of bursting. Check the manufacturer's maximum pressure rating for air
tools and accessories. The regulator outlet pressure must never exceed the
maximum pressure rating.
Risk of property damage. Compressed air from the unit may
contain wa t er condensation and oil mist. Do not spray un f il t ered air at an
item that could be damaged by moisture. Some air tools and accessories
may require filtered air. Read the in s truc t ions for the air tools and
accessories.
How to Start
1.
Turn the Off/Auto switch to "AUTO" and allow tank pressure to build. Motor
will stop when tank pressure reaches "cut-out" pressure.
2.
Turn the regulator knob clockwise until desired pressure is reached. The
compressor is ready for use.
14 - ENG