_Origo_2000_2500_4100_4300.book Seite 14 Freitag, 8. Januar 2010 3:35 15
Using the stove
8
Using the stove
8.1
Filling-in denatured alcohol
Caution! Danger of injury!
d
Never pour fuel through the burner openings in top of the stove
(fig. 1, page 2).
Overfilling, spilt alcohol and hot objects can cause severe burns.
Ensure all burners are turned off:
– operation with denatured alcohol: slide the control fully to right
– operation at the 230 v mains (2500 and 4300 only): switch heating
elements off
Ensure the stove is cooled down to room temperature.
If applicable, remove the cutting board or lift the glass lid (both
accessory).
Pull the latch forward (fig. 4, page 3) and lift the stovetop.
Check canister opening ensuring there's neither fire nor glow.
Take out the canister.
Hold the canister tilted down (fig. 5, page 3).
Fill the denatured alcohol through the wire mesh into the opening of the
canisters.
The maximum capacity per canister must not exceed 1.2 l.
Check the fuel level by tilting the canister vertically (fig. 6, page 3).
Keep it in this position for 20 s, to make sure it's not overfilled. In addi-
tion, in the case of accidental overfilling you can get rid of the surplus
fuel.
The maximum fuel level is reached when the fuel is visible at the bottom
of the opening.
Note
I
The stove will operate even if the canister isn't filled with the
maximum capacity.
Wipe possible spilt alcohol off the outside of the canister.
Replace the canister.
14
Dometic ORIGO