The MISE electronic control unit can be used to control 1 motor with power not exceeding 750W.
a) The wire connections and the operating logic should be in compliance with regulations in force.
b) The cables featuring different voltage should be physically separated, or adequately insulated by an
additional insulation of at least 1 mm.
c) The cables should be further fastened in proximity to the terminals.
d) Check all connections before powering the unit.
e) Check that setting of the Dip-Switches are the required ones.
f)
Normally Closed inputs which are not in use should be short-circuited.
Terminal No.
1-2
3-4-5
2-4
6
7
8
9
10
11
12-13
14-15
16-17
18-19
J4
The control unit is provided with a "TEST" push button with the same functions of the Step-by-Step push
button. This is useful to control the automatic system during installation.
1) Cut off power supply.
2) Manually release the gate wings, move them to about half-stroke and block them again.
3) Reset power supply.
4) Send a step-by-step control signal through "TEST" push button, P.P. input or radio control.
5) The door should open. If not, it is sufficient to invert the move wires (3-5) of the motor and of the limit
switches (6-7).
6) Adjust Times and Operating logic.
TW
The opening and closing maximum movement is adjusted by this trimmer.
It should be preset to about 4s more than the actual stroke of the automatic system.
The adjustment ranges from 3s minimum to 180s maximum.
TCA
It allows to adjust the automatic closure time.
Check the Dip-Switch N°1= On.
The adjustment ranges from 1s minimum to 180s maximum
6
INPUT/OUTPUT FUNCTIONS
Function
Description
Power supply
Input, 230Vac 50Hz (1-Phase/2-Neutral)
Motor
Connection to motor : (3-move/4-Com/5-move)
LAMP
Output, connection of Flashing light 230 Vac 40W max.
SWO
Input, OPENING limit switch (N.C. contact)
SWC
Input, CLOSING limit switch (N.C. contact)
PHOT
Input, connection of safety devices, N.C. contact (e.g. photocells)
STOP
Input, STOP push button (N.C. contact)
COM
Common, for all control inputs.
Step-by-Step
Input, step-by-step push button (N.O. contact)
24Vac
Output: power supply of accessories, 24Vac/200mA max.
Voltage-free contact. Uutput, configuration by means of Dip-switch 5.
DIP5 OFF: Open gate LED connection, 24 Vac/3W max.
SCA/Lock
DIP5 ON: Connection to optional Lock card to control the electric lock.
Do not connect the electric lock directly to the output.
Output, second radio channel of the receiver. N.O. voltage-free contact.
RX 2ch.
Activated only in presence of insertable, two-channel receiver (MISE-
RE)
Connection of the insertable radio receiver card aerial and incorporated
Aerial
radio module (18-screen/19-signal).
Insertable connector for two-channel radio receiver (MISE-RE)
Radio
Built-in radio receiver in model (MISE-RI)
To check wire connections:
MISE Control Unit
GENERAL WARNINGS
Note:
Trimmer functions