DIP 1 "TCA"
The automatic closure is enabled or disabled.
Off: disabled automatic closure
On: enabled automatic closure
DIP 2 "Cond."
The multi-flat function is enabled or disabled.
Off: disabled multi-flat function.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the
transmitter have no effect in the opening phase.
DIP 3 "Phot.Op"
The photocells are activated or deactivated in the opening phase.
Off: activated photocells during opening
On: deactivated photocells during opening
DIP 4 "P.P. Mod"
The operating mode of the "P.P. (Step-by-Step) Push button" and of the transmitter
are selected.
Off: Operation: APRE > STOP > CHIUDE > STOP >
On: Operation: APRE > CHIUDE > APRE >
DIP 5 "Sca/Lock"
The operating mode at output at terminals 14/15 is selected.
Off: Output, open gate LED
On: Output, impulse for the control of the Lock card for electric lock
DIP 6 "Radio"
The programmable code transmitters are enabled or disabled (Not used by MISE-
RE).
On: Radio receiver enabled only for variable code transmitters (rolling-code).
Off: Receiver enabled for variable code transmitters (rolling-code and programmable
code transmitters (self- learning and Dip/switch) .
DL1 LED (green) can indicate the following status:
On: Motor in the closing phase
Off: Motor in the opening phase
Slow flashing: Unit powered by mains power supply
Rapid flashing : Activation of one input (6-7-8-9-11)
DL2 LED (red) is used only form model MISE-RI (see radio configuration)
The MISE-RI control unit is equipped with an incorporated radio module to receive signals from both fixed code
and variable code remote controls (see functions of Dip-switch 8), with frequency of 433.92MHz.
To use a remote control, its code should be copied first. The memorization procedure is shown hereunder. The
device is able to store up to 64 different codes in memory.
To memorize a new transmitter with activation of the P.P. (step-by-step) function
- Press PGM button once for 1s, the DL2 LED starts flashing with 1s pause.
- Within 10s, press the transmitter push button which should be stored in memory with P.P. function.
To exit the programming mode, wait for 10s or press the PGM button for 1s, the DL2 LED switches off.
To erase all transmitter codes from memory
- Keep the PGM push button pressed for 15s, the DL2 LED starts flashing rapidly and switches off at completion
of erasing.
- Release the PGM push button; the memory is now deleted and the DL2 LED starts flashing regularly again
with a 3s pause.
NOTE:
The transmitters are stored in a EPROM (U5) memory which can be extracted from the control unit and inserted
in a new MISE-RI control unit, should the control unit be replaced.
For safety reasons, the transmitter codes cannot be stored in memory during the motor opening/closing
phases.
If, when entering the memorization procedure of transmitters, the DL2 LED shows a long flash and switches off,
this means either the receiver memory is full and no further transmitter codes can be stored in memory, or the
transmitter used is not compatible.
Dip-Switch functions
LED Functions
Built-in receiver configuration (ONLY MISE-RI)
7