Mitsubishi Electric s-MEXT 006 Manual De Instrucciones página 35

Para un uso seguro y correcto, lea este manual y el manual de la unidad exterior antes de la instalación
Ocultar thumbs Ver también para s-MEXT 006:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 130
UM_s-MEXT_ME18relC_00_11_18_ML
Mask of the terminal
8
LAN
1:
2:
4:
5:
7:
8:
10:
9
99.9
99.9
99.9
99.9
99.9
99.9
99.9LAN:Local Unit
Temp.(°C)
10
LAN
1:
2:
4:
5:
7:
8:
10:
11
01
LAN ADL
24.0°C
12
01
LAN APL
Current
0020 Pa
Target
0020 Pa
APL
Local 0019 Pa
Status
On target
13
Target
02500
m3/h
Current
02000
m3/h
Status
In Regulation ...
14
Target
0020
Pa
Current
0020
Pa
Status
On target
15
DT 03.0
T.INT
24.0
Status
Enabled
Position ALL INTERNAL
000%
16
000.0kg/h
A 00.0
µS/cm000
Alarm
code:00
USER MANUAL
Description of the mask
3:
Local network (LAN) status display mask. This mask is displayed only at the Master unit (LAN
address=1). Visible if the local network (LAN) is configured
6:
Unit operating
9:
Unit not operating
If the ADL LAN function is enabled:
Mask that displays all the temperature values read by the units on the pLAN network. This mask is
99.9
displayed only at the Master unit (pLAN address=1).
99.9
Visible if the pLAN is configured
99.9
Local network (LAN) status display mask. This mask is displayed only in the Slave unit (LAN
3:
address=2÷10).
6:
Visible if the local network (LAN) is configured
9:
Unit operating
ADL pLAN function operation status display mask. This mask is displayed for all the units (pLAN
address=1 to 10).
24.0 °C
Visible if the pLAN is configured and the ADL function is active
23.9 °C
APL pLAN function operation status display mask. This mask is displayed for all the units (pLAN
address=1 to 10).
Visible if the pLAN is configured and the APL function is active
0020 Pa
Constant Capacity operation display mask.
Visible if the function is configured
Constant Head operation display mask.
Visible if the function is configured
Direct Freecooling function operation display mask.
Visible if the function is configured
T.EXT
Internal and external T display and Direct freecooling status
21.0
Damper position (internal only, mixing, external only) and opening percentage
The image graphically describes the Freecooling damper position.
Humidifier operation status display mask.
Visible if humidifier is present
Warning
code:0
Unit in stand by
Unit in rescue mode
Unit with Hot-Spot protection
ADL enabled
Unit not operating
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
36
Unit with Cold-Spot protection
ADL operating limit reached