Above
Grade
fast beep
4. Use the marking notches (20) to accurately mark the position of the
laser beam.
MOUNTING ON A GRADE ROD (FIG. F, G)
1. To secure your detector to a grade rod, fi rst attach the detector to the
clamp by pushing in on the clamp latch (26). Slide the tracks (27) on
the clamp around the rail (28) on the detector until the latch (29) on the
clamp pops into the latch hole (30) on the detector.
2. Open the jaws of the clamp by turning the clamp knob (31)
counterclockwise.
3. Position the detector at the height needed and turn the clamp knob
clockwise to secure the clamp on the rod.
4. To make adjustments in height, slightly loosen the clamp, reposition and
retighten.
Detector Cleaning and Storage
• Dirt and grease may be removed from the exterior of the detector using
a cloth or soft, non-metallic brush.
• The Berner digital laser detector is rain resistant but not immersible. Do
not pour water on the unit or submerge it under water.
• The best storage place is one that is cool and dry—away from direct
sunlight and excess heat or cold.
20
INDICATORS
Slightly
On Grade
Above
Grade
fast beep
steady tone slow beep
Slightly
Below
Below
Grade
Grade
slow beep