Note : if your alarm does not succeed in detecting the fall in less than 12 seconds, it
may be necessary to shorten the plunger tube.
If this turns out to be necessary, only cut the tube by 2 cm at a time, and repeat the
test after each cut.
In any case, the end of the plunger tube must still be more than 14 cm beneath
In any case, the end of the plunger tube must still be more than 14 cm beneath
the water.
It is also necessary to take into account the possibility of a low water level
during periods of high evaporation.
Test result
The fall is detected in less than 12
seconds (maximum)
It takes more than 12 seconds to
detect the fall
The fall is not detected
At the end of the tests, the Gre By VISIOPOOL® alarm will automatically return to
surveillance mode once the pool water has become still again, which can take up to
12 minutes.
As it swaps to surveillance mode, the alarm emits a series of bleeps in quick succession
and the red LED starts to blink.

Alkaline Batteries

Despite all care taken in the choice of batteries, it can happen that unforeseeable
storage may have weakened their performance. If the batteries are weak, three
very quick "bleeps" will sound every 45 seconds or so until the batteries have been
changed.
The batteries are guaranteed to last 2 years in normal use (that is, without excessive
triggering of the alarm).
When replacing them, always use batteries of exactly the same characteristics and
power. So as not to pollute the environment, return dead batteries to a proper
reprocessing centre (waste collection site, recycling point).
Page 10
Alarm for swimming pool GRE by VisioPool® - Instruction manual- User Manual
Valid
Action
Yes
Stop the siren
No
Repeat the test or contact your
vendor or ACIS.
No