PIPE ASSEMBLY
Insert the PVC Ø9 x Ø13 pipe in the PVC Ø12
5
x Ø16 pipe and glue with Loctite (in the Piccolo
evaporator only*).
Insert the PVC pipes in the evaporator's run-off
6
pipe and run to the outside (if necessary, make
a Ø22 borehole and position bushing to run the
wastewater pipes to the outside).
Caution: Run-off pipes should have the descent
necessary to run off the water, avoiding any
loops or constrictions.
6
Cut the run-off pipes to the required size and
7
position the drainage valve. Secure with cable
ties.
6
Wastewater
run-off
5
8