Driving mode: power supply from the 12 V battery with motor switched
off.
CA2500, B2200
If the inverter switches off due to low voltage in the supply battery
(10.5 V), no voltage will be supplied to the socket and the roof air
conditioner switches off. The inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's
activation point, the socket is supplied with voltage again.
You have to switch on the roof air conditioner again manually, as the
control electronics need to be reactivated after a lack of voltage.
B1600
If the inverter switches off due to low voltage in the supply battery
(10.5 V), no voltage will be supplied to the socket and the roof air
conditioner switches off. The inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's
activation point, the socket is supplied with voltage again.
The roof air conditioner starts automatically.
Driving mode: power supply from the 12 V battery with motor switched
on.
In driving mode, the starter and supply battery are electrically connected
when the light system is active. This means the supply battery can be
charged from the light system.
Starter batteries may not be discharged as much as supply batteries. To pre-
serve the starter battery, the charging current distributor separates the starter
battery from the supply battery, if the charging voltage in the starter battery
drops below 10.5 V. This also ensures that the starter battery is charged be-
fore the supply battery.
CA2500
If the charging voltage regulator cuts the connection to the supply battery
due to low voltage, it switches off the compressor in the roof air condi-
tioner at the same time. The inverter remains active and has voltage in
its socket.
As soon as the voltage in supply battery has reached the switch-on point
in the charging current distributor, the compressor in the roof air condi-
tioner switches on again.