DMX512 Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This start address is the channel number from which the device starts to "listen" to the DMX
controller. Enter the correct number and read it from the display located on the base of the
VDPLMS1.
You can use the same starting address for a whole group of devices or enter an individual one for
every device.
When all devices have the same address, all the VDPLMS1s will "listen" to the control signal on one
particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set different addresses, each device will "listen" to a separate channel
number. Changing the settings of one channel will only affect the device in question.
In the case of the 5-channel VDPLMS1, you will have to set the start address of the first VDPLMS1
to 1, the second VDPLMS1 to 6 (1 + 5), the third to 11 (6 + 5) and so on.
DMX Values per Channel
channel
function
1
2
pan speed
3
auto programs
4
strobe
5
dimmer
7. Changing the Lens
This pin spot comes with spare lenses. To change to lens, proceed as follows:
• The lens is fixed into the aperture with a ring. Carefully pull out this ring to free the lens. Make sure to
do this over a towel so as to not break the when dropped.
• Take out the lens and replace with another lens of your choice. Place the lens with the convex side on
the outside.
• To fix the lens, gently press the ring and push it against the lens until it snaps into place.

8. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting
supports, do not change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the
device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
24.01.2011
from
pan
000
000
000
007
027
047
067
087
107
127
147
167
187
207
227
000
009
127
192
255
000
VDPLMS1
to
description
255
pan movement 0° ~ 540°
255
fast > slow
006
no function
026
auto 1
046
auto 2
066
auto 3
086
auto 4
106
auto 5
126
auto 6
146
auto 7
166
auto 8
186
auto 9
206
auto 10
226
auto 11
255
auto 12
008
no function
126
open pulse effect
191
strobe 0% ~ 100%
254
close pulse effect
255
no function
255
dimmer 0% ~ 100%
6