Address setting menu in the event of more than one headend being connected to the distribution and selec-
tion of the operational module modes: master, slave, stand-alone.
In order to use the modules in the Master and Slave mode, perform the following procedure:
•
Make sure that the CAM and the smart card allow the simultaneous decoding of more than one program
belonging to the same transponder
•
Set the receiver in the correct mode (Master or Slave) by entering the "SETTING RECEIVER MODES"
menu
•
Connect the Master Module to its Slave modules by using the supplied flat cable
•
In the Master module, select the channels encrypted of the transponder under decoding that you want
to supply to the Slave modules. In order to do this, enter the "SETTINGS – CI PROGR. LIST" menu
and add the channels. The asterisk on the left of the program name (*) 1/N PROGRAM 1 shows that the
program is being decrypted.
See figure 12 for an example.
•
Procedure to modify the headend address in the event that more than one SIG9808CI unit is being used:
•
Enter the "SETTINGS" – "HEADEND ADDRESS" menu
•
Set the headend address number by using the arrows or the keyboard.
•
On the TPE display, the word "Wait ..." will appear (the wait can last up to 30 seconds)
•
Scan the modules: SETUP HEADEND --> SCAN HEADEND
•
The TPE checks the headend modules; when the number of installed modules is reached, press the "X"
key of the TPE
•
Enter the "HEADEND SETUP" menu
•
Save with the TPE "S" key.
SETTING
Choose the program the
CAM will decrypt
Confirm the settings by pressing the
4.10 SETTINGS MENU
RECEIVER
STAND-ALONE
MODE
CI PROGRAM
1/N PROGRAM 1
LIST
REMOVE
HEADEND
0
ADDRESS
after the modules programmation.
SLAVE
N/N PROGRAM N
Enter with
ADD
Confirm by
15
0, 1, ..., 15
key; save the settings by pressing the S key
33
Stand-alone
Master
Slave
"Not available": module in
slav e or stand-alone mode
Add or remov e the channel that
is to be av ailable f or the Slav es
modules
"Not allowed": operation cannot
be executed, programming error.
"Not executed": receiv er is
busy , try again .
Manual setting of the
headend address.