Fermax DIRECT DUOX Manual De Instalador página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

DUO
DUO
X DIRECT
X DIRECT
DUOX DIRECT
DUO
DUO
X DIRECT
X DIRECT
DUO
DUO
DUOX DIRECT
X DIRECT
X DIRECT
X DIRECT
DUO
DUO
X DIRECT
No es necesario segregar la instalación según ésta jerarquía ya que el sistema se
adapta a las necesidades de la instalación.
NOTA IMPORTANTE:
Programación de parámetros por el instalador.
Para programar - modificar dichos parámetros ver «Seccion II: Manual de Programación»,
(al final de este manual).
EN
MASTER Panel:
Programming is always done from the panel activated as MASTER.
Any installation can only have one MASTER panel at a time, whether a single or
multiple block installation, once configured as a sub-block, block or general entrance.
A street panel is configured as a MASTER via the SW1 amplifier button. If the SW1
button is pressed 3 times quickly, it is activated as a MASTER panel and a
confirmation tone sounds (beep-beep). You can also configure it via a code on the
keypad, see Section II.
When a panel is selected as MASTER, it notifies the rest of the situation and if
another was previously configured, it would automatically stop being so.
If there are various blocks in an installation, we recommend using the general
entrance panel as MASTER since it allows you to program all of its telephones.
Once having completed the terminal´s configuration, we recommend deactivating
the MASTER panel to avoid accidentally reprogramming terminals.
The panel deactivates itself from master mode following the same activation
procedure: 3 quick presses of the SW1 button. A deactivation tone sounds (beep-
bop). You can also deactivate it via a code on the keypad, see Section II.
Configuration - Programming the Amplifier
The DUOX amplifier can be configured to allow for the operation as a general entrance,
block entrance or sub-block entrance.
The DUOX system uses 6 digit house terminal addresses.
These call code digits are organised as follows: BBSSNN:
- BB: indicates the Block number, (from 00 to 99).
- SS: indicates the sub-Block number, (from 00 to 99).
- NN: indicates the sub-Block house number, (from 00 to 99).
You do not have to segregate the installation according to this hierarchy since the system
adapts to the installation´s needs.
IMPORTANT NOTE:
Programming the installer´s parameters.
To program or change these parameters see «Section II: Programming Manual», (at the
end of this manual).
Platine MASTER:
F
La programmation se fait toujours à partir de la platine activée en tant que
MASTER.
Quelle que soit l'installation (un seul bâtiment ou plusieurs), il ne peut y avoir
qu'une seule platine MASTER à la fois, qu'elle soit configurée comme platine
de sous-bâtiment, de bâtiment ou d'entrée générale.
Pag 12

Publicidad

Tabla de contenido
loading

Tabla de contenido