Hand Held Digital Alarm Thermometer
UK
Safety Tips
Clean the probe immediately after each measurement to avoid cross contamination.
Do not expose the appliance to temperatures over 50ºC/122ºF or use in ovens.
Installation
1.
Open the battery compartment on the bottom of the appliance.
2.
Insert the battery (Negative (-) terminal first).
3.
Pull out as much of the probe cable as required.
4.
Close the battery cover.
Operation
Temperature Measurement
1.
Press the On/Off button to power up the thermometer.
2.
Insert the probe approximately 25mm (1") into the foodstuff.
3.
The temperature of the foodstuff is displayed when the value remains constant.
Units of Measurement
1.
Press and hold the ºC/ºF button for three seconds to alternate between Centigrade and Fahrenheit.
Data Hold
1.
Press the HOLD button to keep the current reading displayed.
2.
Press the HOLD button again to resume normal operation.
Maximum/Minimum Readings
The thermometer can store and display the maximum and minimum temperature readings taken since the last reset:
1.
Press the MAX/MIN button. The MAX icon flashes and the maximum temperature taken displays on the screen.
2.
Press the MAX/MIN button again. The MIN icon flashes and the minimum temperature taken displays on the screen.
3.
Press the button again to resume normal operation.
Note: To reset the memory turn the thermometer Off and then On again. Always reset the
memory before taking new readings to ensure accuracy.
High/Low Temperature Alarm
The thermometer can sound an alarm when a set temperature range is exceeded.
1.
Press the SET button. The HI value flashes on the display.
2.
Press the
or
button until the required maximum temperature is displayed.
3.
Press the SET button to confirm. The LO value flashes on the display.
4.
Press the
or
button until the required minimum temperature is displayed.
5.
Press the SET button to confirm and return to normal operation.
When the alarm sounds; press any button to turn it Off.
Note: The appropriate icon on the display (HI or LO) continues to flash until the temprature returns
to within the set range.
To permanently turn the alarm Off, follow the steps above but press the
display.
Technical Specification
Temperature range
Temperature reading accuracy
Resolution
Alarm Setting Resolution
Temperature display refresh rate
Display size
Battery
Cable length
Probe size
Thermometer dimensions (hxwxd)
Ambient operating temperature
Troubleshooting
If the appliance ceases to function correctly, press and hold the red RESET button (situated on the back of the appliance)
using a pointed instrument.
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise, without the prior written permission of HYGIPLAS. Every effort is made to ensure all details are
correct at the time of going to press, however, HYGIPLAS reserve the right to change specifications without notice.
Telephone Helpline: 0845 146 2887 (United Kingdom)
button when the HI and LO values flash on the
-50~200ºC/-58~392ºF
± 3ºC/5.4ºF between -50~-20ºC/-58~-4ºF
± 1ºC/1.8ºF between -19.9~119.9ºC/-3.8~247.8ºF
± 2ºC/3.6ºF between 120~200ºC/248~392ºF
0.1º over full range
1º over full range
1 second
19(h) x 48(w) mm
1 x AAA 1.5v
1 metre
3.5(Ø) x 115(l) mm
116 x 78 x 28 mm
0~50ºC / 32~122ºF