Water inlet: This indicates the selection of the required water inlet.
Hot water: Load water from the hot water inlet (Yes/No).
Cold water: Load water from the cold water inlet (Yes/No).
Auxiliary: Load water from the auxiliary water inlet (Yes/No).
Water adjustment: Load water from one or other inlet depending on the temperature
(Yes/No).
T1, T2, T3: Load water from any of the tanks if recovery KIT is fitted.
Drainage: This displays whether the water should be drained at the end of the cycle,
indicating which outlet should be used if the recovery kit is active.
Cooling: Option that permits the temperature in a cycle to be lowered before drainage or
going to the next cycle. Configurable parameter only if the cycle temperature is equal to or higher
than 40ºC (104ºF). Range can be configured from 30ºC (86ºF) to cycle setting.
In addition to selecting the cooling value, there is a button to enable or disable this option.
Dispenser 1.8: Each dispenser can be activated independently, and the following
parameters must be configured if it is activated:
Start: If dispenser X is active, indicate when this dispenser should start dosing.
o
o
o
Time: Time, in seconds, of dispenser X. Range can be configured from 0 to 99.
Delay: Delay, in seconds, of dispenser X. From the moment the programme reaches the
start point indicated, the dosing will be delayed for the time indicated. Range can be
configured from 0 to (cycle time-dosing time).
Safety level (ML): Start dosing when the safety level is reached.
Level (L): Start dosing when the defined level is reached.
Temperature (T): Start dosing when the defined temperature is reached.