Trouble-Shooting - Berner BHPC 150-1 4-in-1 Lance Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 85
BHPC 150-1 4-in-1 Lance
DE

9 Trouble-shooting

EN
FR
Please ensure that you check the following before contacting the BERNER service organization:
IT
Symptom
Machine refuses to start Machine not plugged in
ES
NL
Fluctuating pressure
DA
NO
Motor busses
SV
Machine stops
FI
PT
Fuse blows
Machine pulsating
Machine often starts
and stops by itself
Machine starts, but
no water comes out
Pump pressure drops
In case problems other than the above occur, please contact your local BERNER distributor.
40
Cause
Defective socket
Fuse has blown
Defective extension cable
Pump sucking air
Valves dirty, worn out
or stuck
Pump seals worn out
Low voltage or
low temperature
Fuse has blown
Incorrect mains voltage
Thermal sensor activated
Nozzle partially blocked
Fuse too small
Air in inlet hose/pump
Inadequate supply of
mains water
Nozzle partially blocked
Water fi lter blocked
Hose kinked
Pump/spray handle is
leaking
Pump/hoses or accessory
frozen
No water supply
Water fi lter blocked
Nozzle blocked
Button for regulation of
pressure / water volume not sure.
correctly adjusted
Recommended action
Plug in machine.
Try another socket.
Replace fuse. Switch off other machines.
Try without the extension cable.
Check that hoses and connections are air-
tight.
Clean and replace or refer to local BERNER
distributor
Clean and replace or refer to local BERNER
distributor.
Activate the trigger of the spray handle.
Replace fuse. Switch off other machines.
Check that the mains voltage corresponds
to specifi cation on the model tag.
Leave the washer for 5 minutes to cool
down.
Clean the nozzle (see section 8.2)
Change to an installation higher than the
amp. consumption of the machine.
You may try without the extension cable.
Allow machine to run with open trigger until
regular working pressure resumes.
Check that the water supply corresponds to
specifi cations required (see model tag)
NB! Avoid using long, thin hoses (min. 1/2")
Clean the nozzle (see section 8.2)
Clean the fi lter (see section 8.1)
Straighten out hose.
Contact your nearest BERNER Service
Centre.
Wait for pump/hoses or accessory to thaw.
Connect inlet water.
Clean the fi lter (see section 8.1)
Clean the nozzle (see section 8.2)
Adjust the button to correct working pres-
Original Instructions