AUTOMATIC PROCEDURE
In the automatic mode, the recovery and recycling, oil discharge, and vacuum operations are
performed automatically. New oil reintegration must be performed manually. The machine then
goes on to automatic gas charging.
Connect the hoses to the A/C system with the quick-connect couplings bearing in mind that
BLUE must be connected to the low-pressure side and RED to high pressure. If the A/C
system is equipped with a single quick-connect coupling for high or low pressure, connect only
the relative hose.
Check that the high- and low-pressure taps are closed. Start the vehicle for about 5 to 10
minutes. Switch off the vehicle engine.
The machine is equipped with a 4-line LCD display, maximum 20 characters per line. On the
menus the selected line flashes; in this manual it is enclosed in quotation marks.
Select AUTOMATIC PROCEDURE and press the ENTER key.
The following message appears:
Press ENTER to continue – the following screen opens:
Key in the vehicle's licence plate using the ↓↑ arrows to move around the licence plate
number. Then press "ENTER" to confirm.
NOTE: The numerical keys include an alphabet similar to that for text messages, for example:
press "2" once to display "A", twice to display "B", three times for "C" and four time for "2".
The following screen is displayed:
NOTES:
xy
Default values extrapolated from a previous automatic procedure.
To edit the data proceed as follows:
Edit VACUUM data:
Use the arrows ↓↑ to select VACUUM and key in the new value (using keys 0 to 9).
INSTRUCTIONS MANUAL
WARNING
USING PAG OIL OR TRACER
IN HYBRID VEHICLES CAN
DAMAGE THE COMPRESSOR
USE SPECIFIC OIL WITH A
SEPARATE DEVICE
Press ENTER
Enter licence plate
............
Press ENTER
VACUUM
xy min
REFILLING
xy g
START to continue
-11-