Device overview / Function description
1
2
3
4
5
Fig. 1
1 Rotor
2 Liquid end
3 Metering hose
4 Hose connector, suction side
5 Hose connector, discharge side
6 Rollers
7 Wall bracket
8 Rear housing section, motor
9 Upper housing section, motor
10 Transparent cover
22
4

Device overview

6
7
A Power end
B Liquid end
5

Function description

The rotor is driven by a synchronous gear motor. Rollers are
attached to the ends of the rotor and these press the metering
hose against the inner arch of the liquid end.
The metering function of the peristaltic pump is caused by the
rollers rotating and forcing the liquid out of the metering hose into
the discharge hose. The pump is primed by the action of the
metering hose regaining its original shape.