and the connections should be protected and
adapted to the cable section used.
The electrical connection must be carried out by a
qualified electrician and must be compliant with the
standard: NF C 15-100 (publication 2002).
4.4 Example of an electrical set-up:
5. Commissioning
5.1 Stabilizer
The use of a stabilizer, 10 g/m3
water, is strongly recommended in very hot
weather to avoid chlorine evaporation and to
lessen corrosion.
Maximum concentration: 50 g/m3
PLEASE NOTE:
Too LOW a concentration of stabilizer will
double chlorine consumption in your pool! On
the other hand, too HIGH a concentration of
stabilizer will cancel out the chlorine effect!
If the pool treatment is done by means of
chlorine tablets, measure the concentration of
stabilizer
present
in
concentration exceeds 50 g/m3, replenish part
of the water before adding the salt.
5.2 Salt
Pour the salt directly into the pool, while the
filtration is running.
chlorinator until the salt has been completely
dissolved
Dosage:
4 grams per liter or 400 kg for 100 m3
Verification of the dosage is done with the test
strips provided.
5.3 Switching on
- Turn on the chlorinator switch: "On" (Marche) and
adjust to maximum production, leaving the filtration
24/24 hrs until the desired chlorine concentration is
reached (minimum 0.5 ppm).
to 20 g/m3
in
the
water.
If
the
Do not turn on
the
101449 Installation and user manual
- Turn the filtration onto automatic mode, and
regularly check the chlorine concentration.
- If necessary, adjust the setting if the desired
chlorine concentration is exceeded.
The electrode will automatically be powered-up
after a time-lag period.
After switching on the box, wait 2 minutes before
adjusting the flow using: + or - .

- Factory settings:

4 A - maximum
model 30
-
7 A - maximum
model 55
-
model 95
- 10 A - maximum
6. Flow switch (optional)
We recommend installing a flow switch in the
following cases:
filtration pump situated above the water
level (risk of loss of priming)
chamber installed in a by-pass set-up.
Operating principle:
If the flow is accidentally stopped, or when there is
counter-flushing and, in all cases, when water flow
speed is less than 2.9 m3/h, the detector will cut
off chlorine production.
Installation:
(see diagram paragraph 3)
Install the pipe saddle (50 or 63, to be specified)
which should be placed before the electrolysis
chamber and preferably positioned on horizontal
piping.
The arrow that is on the detector head should be
positioned toward the direction of flow. Connect to
the chlorinator unit.
NEVER
INSTALL
THE
DOWNWARD FLOW
A poorly-positioned detector will hinder chlorine
production and error "99" will blink on and off.
DETECTOR
ON
14