Installation Instructions; Flow Diagram - Hansgrohe Talis 32440000 Instrucciones De Montaje

Ocultar thumbs Ver también para Talis 32440000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport dam-
ages. After it has been installed, no transport or surface
damage will be honoured.
• The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
• The plumbing codes applicable in the respective coun-
tries must be oberserved.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with hydraulically
and thermically controlled continuous flow heaters if the
flow pressure is at least 0,15 MPa.
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Shower filter seal dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't re-
moved
- Shower filter seal dirty
- check valve hasn't moved back
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continuous
flow water heater is not recommended.
Maintenance (see page 40)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions (see page 36)

Flow diagram

(see page 38)
Operation (see page 39)
Spare parts(see page 34)
Cleaning
see enclosed brochure.
Test certificate (see page 40)
Remedy
- Exchange check valves
- Clean filter seal between shower and
hose
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean filter seal between shower and
hose
- Exchange check valves

Publicidad

Tabla de contenido
loading

Tabla de contenido