Dynamic Fluid Measurement
DATA PACKET
Example: Density Correction Factor change from 1.00000 to 1.10000
8101
Last Audit Date mmddyy
00 00 C8 C8 (Hex), 051400 (Decimal) – May 14, 2000
8103
Last Audit Time hhmmss
00 03 0d 40 (Hex), 200000(Decimal) – 8 PM
8105
Old Value (Decimal Inferred in the 4
00 01 86 a0 (Hex) 100000 (Decimal)
th
4
byte of 8513 = 5 (Decimal Places)
result = 1.00000
8107
New Vaule(Decimal Inferred in the 4
00 01 ad b0 (Hex) 110000 (Decimal)
th
4
byte of 8513 = 5 (Decimal Places)
Rsult = 1.10000
8109
Code Flag
00 26 3a 05 in Hex
nd
2
Byte – 26 (Hex) 38 (Decimal) Meter Density,
rd
3
Byte – Audit Code – 3A(Hex) 58 (Decimal) – Density Correction Factor
th
4
Byte – Decimal Places – 05 (Hex) – 5 Decimal Places
NOTE:
When Audit Code = 180, then the following Modbus Addresses store the
parameters indicated.
8101
8103
8105
8107
8109
P
A
D
R E V I O U S
U D I T
A T A
E-CHART Manual
System Start Date
System Start Time
System Failed Date
System Failed Time
Not Used
A
E
R E A
N D S
www.dynamicflowcomputers.com
th
byte of 8109)
th
byte of 8109)
Modbus Data – 4-31