Dynamic Fluid Measurement
DATA PACKET
Previous Month Data Packet (415, 425)
Monthly archive flow data 415, .425 are fixed length arrays. The data field is used
to address an 7 days individual group record. (available only for version 6.03 or
above)
Number
Day
415
25-31
RTU MOD E -
FUNC
ADDR
CODE
01
03
Re sp ons e
FUNC
ADDR
CODE
01
03
E-CHART Manual
Number
Day
425
25-31
STARTING POINT
HI
LO
01
9f
DATA ...(Repeat n Times)
BYTE
HI
COUNTS
C8
00
www.dynamicflowcomputers.com
Modbus Data – 4-44
# OF POINTS
HI
LO
00
01
CRC
LO
CHECK
01..
CRC
CHECK