Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the
address listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Do not use this range hood with any additional solid state
speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate
for the size of the surface element.

SAFETY INSTRUCTIONS

WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
4. Use an extinguisher ONLY if:
*
CAUTION
1. For general ventilating use only. Do not use to exhaust
2. To avoid motor bearing damage and noisy and/or
3. Your hood motor has a thermal overload which will
4. For best capture of cooking impurities, the bottom of the
5. To reduce the risk of fire and to properly exhaust air on a
6. This product is equipped with a thermostat which may
7. The Jenn-Air hood must be installed with blower models
8. Use with approved cord-connection kit only.
9. Please read specification label on product for further
3
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
- This could cause a violent steam explosion.
A. You know you have a Class ABC extinguisher and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
Based on "Kitchen Fire safety Tips" published by NFPA.
!
hazardous or explosive materials and vapors.
unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.
automatically shut off the motor if it becomes overheated.
The motor will restart when it cools down. If the motor
continues to shut off and restart, have the hood serviced.
hood should be a minimum of 24" and a maximum of 30"
above the cooking surface.
ducted installation, be sure to duct air outside - Do not
exhaust air into spaces within walls or ceiling or into attics,
crawl spaces, or garage.
start blower automatically. To reduce the risk of injury and
to prevent power from being switch on accidentally, switch
power off at service panel and lock or tag service panel.
H325B or H326B only. Other blowers cannot be
substituted. (Blowers sold separately).
information and requirements.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jxt9030bdpJxt9036bdpJxt9048bdp

Tabla de contenido